Technical data

Table Of Contents
SFBs for Compact CPUs
System Software for S7-300/400 System and Standard Functions - Volume 2/2
28-12
A5E00739858-01
Event class
Error code
Explanation
W#16#3402 Wrong target setting. For a rotary axis the target setting must be greater than 0 and
lower than the rotary axis end value.
W#16#3403 Wrong distance setting. The travel distance setpoint for the Relative Step Approach
must be positive.
W#16#3404 Wrong distance setting. The result, the absolute target coordinate, must be greater than
-5x10
8
.
W#16#3405 Wrong distance setting. The result, the absolute target coordinate, must be lower than
5x10
8
.
W#16#3406 Wrong distance setting. The result, the absolute target coordinate, must lie within the
working range (+/- half of the target range)
W#16#3501 Travel distance too long. Target coordinate + actual remaining distance must be greater
than / equal to -5x10
8
W#16#3502 Travel distance too long. Target coordinate + actual remaining distance must be smaller
than / equal to 5x10
8
W#16#3503 Travel distance too short. The travel distance in plus direction must be greater than the
specified cut-off difference in plus direction
W#16#3504 Travel distance too short. The travel distance in minus direction must be greater than
the specified cut-off difference in minus direction
W#16#3505 Travel distance too short or the limit switch in plus direction is already actuated. The
last approachable target in plus direction (working range or travel distance limit) is too
close to the actual position
W#16#3506 Travel distance too short or the limit switch in minus direction is already actuated. The
last approachable target in minus direction (working range or travel distance limit) is too
close to the actual position