Parameters not assigned to the block (Statistical local data):
Parameter Declaration Data
type
Address
(Instance
DB)
Range of
values
Default Description
CHGDIFF_P
STATIC DINT 28
0 to +10
8
pulses
1000 Switch-over
difference plus:
The "Changeover
difference plus"
defines the point at
which the drive
continues its forward
run with creep
speed.
CUTOFF-
DIFF_P
STATIC DINT 32
0 to +10
8
pulses
100 Cut-off difference
plus:
The "Cut-off
difference plus"
defines the cut-off
point at which the
drive forward run
with creep speed is
switched off.
CHGDIFF_M
STATIC DINT 36
0 to +10
8
pulses
1000 Changeover
difference minus:
The "Changeover
difference minus"
defines the point at
which the drive
continues its forward
run with creep
speed.
CUTOFF-
DIFF_P
STATIC DINT 40
0 to +10
8
pulses
100 Cut-off difference
minus:
"Cut-off difference
plus" defines the
point at which the
drive reverse run
with crawl speed is
switched off.
PARA
STATIC BOOL 44.0 TRUE/FALSE FALSE Parameters have
been assigned to
the axis
DIR
STATIC BOOL 44.1 TRUE/FALSE FALSE Actual/last sense of
direction
FALSE = forward (in
plus direction)
TRUE = reverse (in
minus direction)
CUTOFF
STATIC BOOL 44.2 TRUE/FALSE FALSE Drive in cut-off range
(from cut-off position
to the start of the
next run)