Technical data

Table Of Contents
SFBs for Compact CPUs
System Software for S7-300/400 System and Standard Functions - Volume 2/2
A5E00739858-01
28-23
Error Information
Operating mode error (ERROR = TRUE)
The output parameter ERROR is set TRUE if an error is detected. The parameter
STATUS shows the cause of the error.
Event class
Error code
Explanation
W#16#2001 Wrong SFB, use SFB 46
W#16#2004 Wrong channel number (CHANNEL). Set channel "0"
W#16#3001 Run job rejected because of job error in the same SFB call. Correct the respective
JOB parameters
W#16#3002 A change of MODE_IN is not permitted while the drive is in operation. Wait for the end
of the current positioning run.
W#16#3003 Unknown operating mode (MODE_IN). Permitted is 1 (jog), 3 (reference run), 4
(Relative Step Approach) and 5 (Absolute Step Approach).
W#16#3004 Only one start request is allowed the same time. Valid start requests are DIR_P,
DIR_M or START.
W#16#3005 START is only allowed in operating mode ” Absolute Step Approach ”. Start the run
with DIR_P or DIR_M
W#16#3006 DIR_P or DIR_M is not allowed for linear axis and in operating mode "Absolute Step
Approach". Start the run with START
W#16#3007 Axis not synchronized. "Absolute Step Approach" is only possible with a synchronized
axis.
W#16#3008 Clear working range. Return run to working position is only allowed in jog mode.
W#16#3101 Start is not enabled because the axis is not parameterized. Parameterize the
"Positioning" submodule via HWConfig
W#16#3102 Start not enabled because the drive is not enabled. Set "Enable Drive" on the SFB
(DRV_EN=TRUE)
W#16#3103 Start not enabled because STOP is set. Clear the STOP on the SFB
(STOP=FALSE)
W#16#3104 Start is not enabled because the drive is currently performing a positioning run
(WORKING=TRUE). Wait for the end of the current positioning run.
W#16#3105 Start not enabled because at least one error that is pending has not been cleared.
First, eliminate and clear all external errors and the restart the run.
W#16#3201 Wrong speed setpoint SPEED. For positioning with digital outputs only "Creep
speed" (0) and "Rapid speed" (1) are allowed.
W#16#3301 Changeover/cut-off difference is too high. Set a maximum changeover/cut-off
difference of 10
8
W#16#3303 Changeover difference too low. The changeover difference must be higher than /
equal to the cut-off difference.
W#16#3304 Cut-off difference too low. The cut-off difference must be at least half the size of
the target range.
W#16#3401 Target setting out of working range. For a linear axis and Step Approach the target
setting must be within the range of the software limit switches (inclusive).
W#16#3402 Wrong target setting. For a rotary axis the target setting must be greater than 0 and
lower than the rotary axis end value.
W#16#3403 Wrong distance setting. The travel distance setpoint for the Relative Step Approach
must be positive.