Technical data

Table Of Contents
System Status Lists (SSL)
System Software for S7-300/400 System and Standard Functions - Volume 2/2
33-60
A5E00739858-01
Data Record
A data record of the partial list with ID W#16#xy96 has the following structure:
Contents Length Meaning
logadr 1 word Bits 0 to 14: address of the module
Bit 15: 0 = input, 1 = output
System 1 word Identifier for the central module/DP master system ID
/PROFINET IO system ID:
0: central module
1-31: distributed module on PROFIBUS DP
100-115: distributed module on PROFINET IO
API 2 words Configured application profile (Application Process Instance =
API) for a distributed PROFINET device.
Profiles
are sector-specific or technology-specific specifications
that go beyond the PROFINET standard.
Profile 0 means that the data correspond to the specification in
the PROFINET standard.
Station 1 word Rack no./station number/device number
Slot 1 word Slot no.
Subslot 1 word Interface module slot (if not interface module can be inserted,
than specify 0 here)
Offset 1 word Offset in the user data address range of the associated module
Solltyp 7 words Expected type
The expected type is has a hierarchical structure in
PROFINET IO
Word
PROFINET IO
PROFIBUS DP
1: Manufacturer no. or profile
identification (e.g. W#16#FF00 for
PROFIBUS)
0000
2: Device 0000
3: Sequential number or profile index 0000
4: 1
st
word of the double word for
submodule identification
Type identifier
5: 2
nd
word of the double word for
submodule identification
0000
6: 1
st
word of the double word for
interface module identification
0000
7: 2
nd
word of the double word for
interface module identification
0000
Soll_ungleic_Ist_typ 1 word Expected/actual identifier
Bit 0 = 0: expected same as actual
Bit 0 = 1: expected not same as actual
Bit 1 to 15: reserved
reserve 1 word Reserved