Service manual

3-18 SPARC Enterprise T1000 Server Service Manual April 2007
SYS/LOCATE SYS/SERVICE SYS/ACT
OFF OFF ON
--------------------------------------------------------
----------------------------------------------------------
Fans (Speeds Revolution Per Minute):
----------------------------------------------------------
Sensor Status Speed Warn Low
----------------------------------------------------------
FT0/F0 OK 6762 2240 1920
FT0/F1 OK 6762 2240 1920
FT0/F2 OK 6762 2240 1920
FT0/F3 OK 6653 2240 1920
--------------------------------------------------------------------------------
Voltage sensors (in Volts):
--------------------------------------------------------------------------------
Sensor Status Voltage LowSoft LowWarn HighWarn HighSoft
--------------------------------------------------------------------------------
MB/V_VCORE OK 1.30 1.20 1.24 1.36 1.39
MB/V_VMEM OK 1.79 1.69 1.72 1.87 1.90
MB/V_VTT OK 0.89 0.84 0.86 0.93 0.95
MB/V_+1V2 OK 1.18 1.09 1.11 1.28 1.30
MB/V_+1V5 OK 1.49 1.36 1.39 1.60 1.63
MB/V_+2V5 OK 2.51 2.27 2.32 2.67 2.72
MB/V_+3V3 OK 3.29 3.06 3.10 3.49 3.53
MB/V_+5V OK 5.02 4.55 4.65 5.35 5.45
MB/V_+12V OK 12.25 10.92 11.16 12.84 13.08
MB/V_+3V3STBY OK 3.33 3.13 3.16 3.53 3.59
-----------------------------------------------------------
System Load (in amps):
-----------------------------------------------------------
Sensor Status Load Warn Shutdown
-----------------------------------------------------------
MB/I_VCORE OK 20.560 80.000 88.000
MB/I_VMEM OK 8.160 60.000 66.000
-----------------------------------------------------------
----------------------
Current sensors:
----------------------
Sensor Status
----------------------
MB/BAT/V_BAT OK
------------------------------------------------------------------------------
Power Supplies:
------------------------------------------------------------------------------
Supply Status Underspeed Overtemp Overvolt Undervolt Overcurrent
------------------------------------------------------------------------------