7.44 AT^SSCONF SMS Configuration
Test command
AT^SSCONF=?
Response
^SSCONF: (list of supported <ra>s), (list of supported <FF>s)
Parameter
See write command
Read command
AT^SSCONF?
Response
^SSCONF: <ra>, <FF> OK
Parameter
See write command
Write command
AT^SSCONF=
<ra>[,<FF>]
The write command serves to control the presentation of the recipient address
parameters <ra> and <tora>.
Response
OK
Parameter
<ra> Display recipient address
[0] the mobile station shall not display the parameter <ra> and
<tora>.
1 the mobile station shall display the parameter <ra> and
<tora>.
<FF> Display filler bits (numeric)
[0] the mobile station shall display the filler bits
1 the mobile station shall not display filler FF in PDU mode
status reports.
Please note that the setting is stored volatile, i.e. after restart or reset, the de-
fault value 0 will be restored. Also, there is no way to store AT^SSCONF to
the user defined profile.
Reference
Siemens
Note
The parameters <ra> and <tora> appear in the result codes of the AT com-
mands AT+CMGL, AT^SMGL, AT+CMGR, AT^SMGR and the unsolicited re-
sult code +CDS.
The parameter <FF> appears in the result codes of the AT commands