7.2 Modification of Input-Output identification string
In this section the User can modify the identification string (ALIAS) for the device inputs/outputs.
If no changes are made, the factory settings are maintained.
The defined alias will have a maximum length of 10 alphanumeric characters ( 0÷9, A÷Z ). Observe the syntax indicated below.
Note that the characters “space (blank), +, -, _, etc”, are not included and, consequently, are not recognized by the device.
Inputs - Outputs Factory setting Any modification Example Incorrect example
Alarm input IN1 max 10 characters ( 0÷9, A÷Z). ALARM ALARM 1
Relay output 1 OUT1 max 10 characters ( 0÷9, A÷Z). BOILER PUMP+1
Relay output 2 OUT2 max 10 characters ( 0÷9, A÷Z). LIGHTS HOME LIGHTS
Temp. sensor input TEMP max 10 characters ( 0÷9, A÷Z). TEMPEXT TEMPERATURE
Some examples of correct syntax for modifying the identification strings are shown below.
[ALIAS]
SMS command SMS reply Action
ALIAS IN1=ALARM IN1=ALARM identification input 1 with “ALARM”
ALIAS OUT1=BOILER OUT1= BOILER identification relay output 1 with “BOILER
ALIAS OUT2= LIGHTS OUT2= LIGHTS identification relay output 2 with “LIGHTS
ALIAS ANALOG=TEMPEXT ANALOG=TEMPEXT (*) identification analogue input with “TEMPEXT”
(*) factory preset ANALOG=TEMP