: This marketing data sheet is not intended to be used for system design or installation purposes.
For the most up-to-date information, refer to each product’s installation instructions.
Details for Ordering
Shipping Weight
Model
Number
Part
Number
Description
Oz. Kg.
TRI-D 500-896226
Dual-
Input Intelli
g
ent
Interface Module
7 0.2
TRI-R 500-896224
Single-
Input [w/ relay]
Intelligent Interface
Module
7 0.2
TRI-S 500-896225
Single-
Input
Intelligent Interface
Module
7 0.2
Mounting Diagram
Specifications (continued)
The microcomputer chip for the Model TR
I-series of
devices has the capacity of storing
in memory
identification information as well as important
operating status information.
Siemens
Fire Safety innovative technology allows
all Model TR
I-series intelligent interface modules to
be programmed and tested, via Model DPU or the
FP
I-32 Programmer / Tester. Each of these
programmer / testers is a compact, portable and
menu-driven accessory that makes programming
and testing an interface device faster, easier and
more dependable than previous methods.
Model DPU or the FP
I-32 eliminates the need for
mechanical addressing mechanisms (such as:
program jumpers, D
IP switches, or rotary dials),
since either programmer / tester device
electronically sets the address of the Model TR
I-
series into the interface’s microcomputer-chip, non-
volatile memory. Vibration, corrosion and other
conditions that deteriorate mechanical addressing
mechanisms are no longer a cause for concern.
The Model TR
I-series of intelligent interface
modules is fitted with screw terminals for
connection to an addressable circuit, and is fully
compatible on the same circuit with all intelligent
Model FP; Model
IL and Model ID-60-series
detectors; Model MS
I Series addressable manual
stations, or any other addressable intelligent
modules, such as Model CZM or Model
ICP.
All Model TR
I-series intelligent interface modules
are
UL and ULC Listed.
Electrical Ratings
Current Draw:
[Active or Standby]
1.5mA
Model TRI-R Relay Ratings:
Resistive:
4A, 125VAC
4A, 30VDC
Inductive:
3.5A, 120VAC [0.6 P.F]
3.0A, 30VDC [0.6 P.F]
2.0A, 120VAC [0.4 P.F]
2.0A, 120VAC [0.35 P.F]