Commissioning Instructions
Table Of Contents
- 1 Functions
- 2 UI description
- 2.1 Home Page (Navigation function)
- 2.2 Multifunction page
- 2.3 General temperature control page
- 2.4 VRF air conditioner function page
- 2.5 Floor heating function page
- 2.6 Ventilation system function page
- 2.7 RGB dimming function page
- 2.8 Energy metering display function page
- 2.9 Air quality display function page
- 2.10 Background music function page
- 2.11 Setting page
- 2.12 Screen
- 2.13 Administrator function via password
- 2.14 Administrator function via bus
- 2.15 Other pages
- 3 Parameters and communication objects
- 3.1 "General" interface
- 3.2 "Home page" interface
- 3.3 "Function page" interface
- 3.3.1 "Page settings" parameters
- 3.3.2 "Function page" communication objects
- 3.3.3 "Page x - Multifunction (Lighting/Blind/Scene/Value send)" parameters and communication objects
- 3.3.4 "Page x - General Temp. Control" parameters and communication objects
- 3.3.5 "Page x - Enhanced Floor Heating" parameters and communication objects
- 3.3.6 "Page x - VRF interface & Operation" parameters and communication objects
- 3.3.7 "Page x - Ventilation System" parameters and communication objects
- 3.3.8 "Page x - Air Quality display" parameters and communication objects
- 3.3.9 "Page x - Energy Metering Display" parameters and communication objects
- 3.3.10 "Page x - RGB Dimming" parameters and communication objects
- 3.3.11 "Page x - Background Music" parameters and communication objects
- 3.4 "Timer function" interface
- 3.5 "Event Group function" interface
- 3.6 "Logic function" interface
- 4 Icons
- 5 Appendix
Parameters and communication objects
"Function page" interface
3
A6V12035440_en--_c
55 | 121
No.
Name
Object function
Length
Flag
Data type
1
Page x-Icon y
Up / Down
1 bit
CWT
1.008 up/down
The communication object is used to send a telegram value to bus to control the opening/closing of the Roller shutter.
Telegram value:
0: Move up
1: Move down
2
Page x-Icon y
Stop
1 bit
CT
1.007 step
The communication object is used to send a telegram for stopping the blind movement to bus. Telegram value:
1: Stop
No.
Name
Object function
Length
Flag
Data type
1
Page x-Icon y
Recall / Save scene
1 byte
CWT
18.001 scene control
The communication object is used to send a telegram of scene recall or scene storage. The highest bit 1 is the scene storage,
and the highest bit 0 is the scene recall.
3.3.4 "Page x - General Temp. Control" parameters and
communication objects
Parameters
Assign "Page x" as single function –"General Temp. Control" page. General
temperature control could manage the followings:
● Heating / Cooling separately or Heating and Cooling for 2-pipe/4-pipe system
● Temperature setpoint adjustment absolutely or relatively
● 4 operation mode selectable (Comfort, Economy, Standby, Protection)
● PI loop selectable for On/Off, PWM and modulating (continuous) control
● With or without fan speed control
Therefore, it could be configured for many heating and/or cooling applications,
such as fan coil application, chilled ceiling, electrical heating.
Blind (up/down/stop)
Scene control