Vehicle Diagnostic, Testing and Information System VAS 5051B Operating manual A01.4 Ausgabestand: 06.08.
IMPORTANT SAFETY INSTRUCTIONS VA S 5 05 3 VA S 5 05 1 VA S 5 0 52 VA S 50 51 B Safety Instructions Meaning of symbols The safety instructions in the Operating Manual, the Startup/Unpacking Instructions or in other documentation provided, on screen displays on the tester during operation and on the products themselves use symbols with the following meanings: Warning! Text with this symbol contains information for your safety and how you can reduce the risk of severe or fatal injury.
IMPORTANT SAFETY INSTRUCTIONS VA S 5 05 3 VA S 5 05 1 VA S 5 0 52 VA S 50 51 B IMPORTANT SAFETY INSTRUCTIONS 1. Warning! Read all instructions. 2. Warning! Do not operate equipment with a damaged cord or if the equipment has been damaged - until it has been examined by a qualified serviceman. 3. Warning! Do not let cord hang over edge of table, bench or counter, or come in contact with hot manifolds or moving fan blades. 4. Warning! An extension cord is not allowed.
IMPORTANT SAFETY INSTRUCTIONS VA S 5 05 3 VA S 5 05 1 VA S 5 0 52 VA S 50 51 B 7. Warning! Adequate ventilation should be provided when working on operating combustion engines. 8. Warning! Use only as described in this manual. Use only manufactures’s recommended attachments. 9. Warning! When connected to electrical power supply, the devices correspond to protection class 1 and are fitted with a safety-tested power cable.
IMPORTANT SAFETY INSTRUCTIONS VA S 5 05 3 VA S 5 05 1 VA S 5 0 52 VA S 50 51 B 12. Warning! Electrical ignition systems carry currents of up to approx. 30 kV. Observe general safety guidelines for workshops at all times. 13. Warning! If you open the tester or its accessories without authorisation or carry out improper alterations to them, considerable risk to you and to the device may result. 14.
IMPORTANT SAFETY INSTRUCTIONS VA S 5 05 3 VA S 5 05 1 VA S 5 0 52 VA S 50 51 B Warnings because of built-in Bluetooth transceiver 18. Warning! FCC 15.105: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
IMPORTANT SAFETY INSTRUCTIONS VA S 5 05 3 VA S 5 05 1 VA S 5 0 52 VA S 50 51 B 21. Warning! This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Technical Data VAS 5051B 2 Technical Data 2.1 VAS 5051B Operating Unit (Tester) 2.1.1 Operating Data Dimensions (W x H x D) Approx. 410 x 310 x 95 mm Weight Approx. 7.6 kg Ambient conditions Operation Ambient temperature Relative humidity Transportation and storage Ambient temperature Relative humidity +5 to +40 °C by max. +25 °C 10 to 80 %, non-condensing -20 to +60 °C by max.
Technical Data VAS 5051B Power supply from power adapter Current consumption DC 24 V, 5 A Power supply from the battery If the external power supply (power adapter, mains power, vehicle electrical system) is interrupted, the tester is buffered with the battery. Li-ION, 14.8 V Battery type Buffer time Recharge time (on mains) Power supply from the vehicle electrical system Rated voltages Current consumption in the load range Protection Operating manual VAS 5051B A01.4 A5E00309941 //6.8.
Technical Data VAS 5051B External interfaces, wired COM1 (V.24) USB interface Monitor (VGA) Ethernet interface Audio input Audio output Power output Card reader PCMCIA slot DC input Socket panel (test instruments) DIAG URDI DSO1, DSO2 SZ KV TZ T/D External interfaces, wireless IrDA Bluetooth 2.2 9-pin Sub-D connector for RS232/RS485 4 x USB 2.0 standard 15-pin Sub-HD socket RJ45 socket Jack bush 3.5 mm Jack bush 3.5 mm, At 8 W load: 200 mW (at 0.1 % distortion) At 32 W load: 85 mW (at 0.
Technical Data VAS 5051B Mains cable (internal) Plug type Operating manual VAS 5051B A01.4 A5E00309941 //6.8.04// The mains cable (approx. 3 m) is connected to the mains network in the workshop trolley. Plug for non-heating apparatus type C13, EN60320/C13 Variant 1: Schuko plug, Type VII as per CEE(7) VII Variant 2: USA plug, Type 498 G as per NEMA 5-15 08/04 All rights reserved.
Technical Data VAS 5051B 2.3 Test Instruments 2.3.1 Multimeter Caution Maximum voltage of the U/R/D/I measuring lead: DC 50 V or 42 Vpeak Direct voltage at U/R/D/I (Ri ≥ 1 MΩ) Range -2 to +2 V Resolution 0.001 V -20 to +20 V 0.01 V -50 to +50 V 0.01 V Range Resolution Tolerance 0 to 2 V 0.001 V 0 to 20 V 0.01 V 0 to 40 V 0.01 V ±1.5 % of m. ±4 mV ±1.5 % of m. ±40 mV ±1.5 % of m. ±80 mV Range Resolution Tolerance 0 to 2 V 0.001 V 0 to 20 V 0.01 V 0 to 40 V 0.01 V ±5 % of m.
Technical Data VAS 5051B Resistance via U/R/D/I measuring lead The measured current depends on the measurement range and is maximum 5 mA. Range Resolution Tolerance2) 0 Ω to 10 Ω 10 mΩ ±1 % of m. ±5 mΩ 0 Ω to 100 Ω 0.1 Ω ±1 % of m. ±50 mΩ 0 Ω to 1 kΩ 1Ω ±1 % of m. ±1 Ω 0 Ω to 10 kΩ 10 Ω ±1 % of m. ±10 Ω 0 Ω to 100 kΩ 100 Ω ±1.5 % of m. ±100 Ω 0 Ω to 1 MΩ 1 kΩ ±2 % of m. ±1 kΩ 0 Ω to 10 MΩ 10 kΩ ±2 % of m.
Technical Data VAS 5051B Alternating current via current pick-up 1800 A (effective value, 30 Hz to 500 Hz, crest factor max. 3) Range 0 to +900 A Resolution 0.1 A Tolerance ±5.5 % of m. ±2.5 A1) 0 to +1800 A 1A ±5.5 % of m. ±3 A1) ±3.5 % of m. ±2 A1) bis ±1500 A 1) The accuracy of the current pick-up is given only after calibration. Caution Maximum voltage on DSO measuring lead: 400 Vpeak or 400 V DC Direct voltage at DSO1 (Ri ≥ 4 MΩ) Range -1.6 to 1.
Technical Data VAS 5051B 2.3.2 Temperature Sensor T/P measuring input 2.3.3 Pressure Sensor T/P measuring input 2.3.4 The measuring input is designed for connection of a temperature sensor with a PT100 measuring element. The measuring input is designed for connection of a pressure sensor with a 4 mA to 20 mA interface.
Technical Data VAS 5051B Measurement ranges DSO1, DSO2 Differential inputs Range ±0.4 V ±1.6 V ±4 V ±16 V ±40 V ±160 V ±400 V Operating manual VAS 5051B A01.4 A5E00309941 //6.8.04// 08/04 Voltage divider ≥ 4 MΩ, 25 pF against protective conductor potential y deflection 50 mV/DIV 200 mV/DIV 500 mV/DIV 2 V/DIV 5 V/DIV 20 V/DIV 50 V/DIV All rights reserved.
Technical Data VAS 5051B Measuring channels CH1, CH2 Sampling rate Input bandwidth (-3 dB) Sampled-data storage Coupling Measuring channels Measurement inputs max. 40 MHz in channel 1 mode 10 MHz (without sensor) Depth 64 k (meas.vals.)/ channel AC, DC, GND 2 DSO1, DSO2, kV pick-up current pick-up 100 A, 1800 A Pressure or temperature sensor Time base 1.25 µs/DIV 2.
Technical Data VAS 5051B Measurement range kV Range ±8 kV ±20 kV ±40 kV y deflection 1 kV/DIV 2.5 kV/DIV 5 kV/DIV Tolerance ±15 % of m. ±200 V ±15 % of m. ±400 V ±15 % of m. ±800 V The size of the measurement error depends on the ignition cable insulation and applies to use in vehicle systems with mechanical distributors. The kV input and the kV pick-up (ignition voltage adapter) form a capacitive voltage divider.
Technical Data VAS 5051B 2.4 Measuring Leads Diagnostic cable Diagnostic cable, optional Diagnostic adapter Diagnostic cable LT, optional 5m 3m 0.3 m (for testing old vehicles) 3m Cable bend diameter 10 x cable diameter Plug cycles > 1.000 2.5 Mains Cable on Workshop Trolley Mains cable Operating manual VAS 5051B A01.4 A5E00309941 //6.8.04// The mains cable (6 m) can be replaced with a mains cable of the type applicable in the country of use.