Installation Guide

17 © 2014 Siemens Industry, Inc. 813776
Rear-fed, Cord-and-Plug Installation
Mounting
NOTE: Flush mount installations
only, meaning the receptacle is
even with wall in which it is
installed.
§ Locate a stud within the
wall to attach the mounting
bracket.
o For concrete or masonry
walls, install appropriate
anchors.
o Verify that the stud or
anchor and surrounding
materials can handle the
20+ lbs load of the
VersiCharge.
§ Ensure that receptacle can
be flush mount installed to
the left side of the
mounting bracket.
o Receptacle should be
installed prior to
mounting the
VersiCharge to the wall.
o Verify local code with
respect to installation height.
o NEC® 2011 specifies: Indoor (NEC® Article 625.29B) states installation
18 – 48 inches above ground level.
§ Wire a standard NEMA 6(above it is
NEMA 6-50) receptacle using
appropriate wire.
§ Using 7/16 inch socket head and drill,
attach the Mounting Bracket to the wall
using two lag screws provided. Verify
that lag screws are going into the stud.