Installation Guide

26 © 2014 Siemens Industry, Inc. 813776
State Name
Description
Halo Status
Indicator
Power Available 240V or 208V Power Present Off
Ready to Charge EV detected, waiting for charging
command from EV
Green - Solid
Charging Charging EV Green - Fading in
and out
Pause Operation paused Off
Delay Timer Operation awaiting delay timer Off
Remote System is controlled via remote control
interface
Off
Halo Deactvation
The Halo indicator on the versiCharge can be deactivated to marginally lower
power consumption of your device during normal operation. This will prevent the
Halo from illuminating in all states, except the ‘Fault’ state.
§ To de/re-activate the Halo:
o Remove the connector from the EV and place in the connector holster
o Verify that the VersiCharge is in the ‘Power Available’ state by ensuring
that only the ‘Power Available’ indicator is illuminated
o Press and hold both the ‘Pause’ and the ‘Delay Timer’ buttons for 5
seconds. The Halo will blink green three times, and then fade out to off
4.7 Remote Control Interface
The Siemens VersiCharge has a Remote Control Interface that allows charging
to be controlled by an external device. Examples include demand response
switches, building automation systems, digital sensors, etc.
§ To wire a digital input into the dry contact in the connection area located
inside of the VersiCharge, please refer to the installation section 3.6 of this
manual.