Specification

Siemens Industry, Inc.
5400 Triangle Parkway
Norcross, GA 30092
1-800-241-4453
info.us@siemens.com
www.usa.siemens.com/VersiCharge
Subject to change without prior notice
Order No.: PDDS-VERSI-0814
All rights reserved
Printed in USA
© 2014 Siemens Industry, Inc.
The information provided in this flyer contains merely general descriptions
or characteristics of performance which in case of actual use do not always
apply as described or which may change as a result of further development
of the products. An obligation to provide the respective characteristics shall
only exist if expressly agreed in the terms of contract.
All product designations may be trademarks or product names of Siemens
AG or supplier companies whose use by third parties for their own purposes
could violate the rights of the owners. NEC® is a registered trademark of the
National Fire Protection Association.
Wall Mounted EVSE Mounting Bracket
14.5” W x 16.0” H x 6.5” D
(front of unit excluding connector)
15” minimum clearance
recommended for connector
when inserted
2.5” x 16.9”
Install at a minimum of 18” off the ground
VersiCharge Electric Vehicle Chargers
Part number Model
Output
Amperage Color Feeder Location
VC30XXXU* Universal VersiCharge 30 A Grey Rear/Bottom/Hardwired
VC30XXXHW* Hardwired VersiCharge 30 A Grey Hardwired
*’XXX’ serves a s a placeholder for color. Currently a light grey color is available (‘GRY’)
Parameters
Attribute Universal Model Hardwired Model
Essentials
Part Number VC30XXXU VC30XXXHW
Amperage 30 Amps
Input voltage 208 - 240 V
AC
Cord Length 20 ft 14 ft
Wall Weight 14.5 lbs 12.5 lbs
Dimensions 14.5” W x 16.0” H x 6.5” D
Output power 1.2 kW to 1.8 kW
Enclosure NEMA 4 NEMA 1
Plug in Installation Yes (below or behind unit) No
Permanent Installation Yes Yes
Electrical
Circuit requirement 40 Amperes*
Input power connections Line 1, Line 2, Earth Ground
Recommended branch breaker
4 0 A m p ere do u b le pol e
(Siemens: Q240 plug in type, B240 bolt on type)
Mechanical
Connector SAE J1772
Safety
and
Operational
Standards Compliance UL, SAE J1772, NEC® 625
EMC FCC Part 15 Class B
Operating temperature -30°C to +50° C
Storage temperature -40°C to +60°C
Operating humidity Maxiumum 95% non-condensing
*Adjustment of amperage output possible via dial in the unit, will effect the power output of charger.
Accessories
Part number Description Color
VCMNTGBRK Spare Parts Mounting Bracket Black