Installation Guide
17 © 2015 Siemens Industry, Inc. 813776
Using 7/16 inch socket head and drill, attach the Mounting Bracket to the wall using two
lag screws provided. Verify that lag screws are going into the stud.
Before starting the step to hang the
VersiCharge unit onto the mounting bracket,
ensure that the circuit breaker on the circuit for
the receptacle is turned to the ‘OFF’ position.
To hang the unit onto the mounting bracket,
place bottom mounting tab into corresponding
slot in mounting bracket. Plug cord into
receptacle. Rotate the unit towards the wall so
that the hook on the unit goes over the top
mounting bracket. Turn the breaker for this
circuit back to the ‘ON’ position to power up
the VersiCharge.
Secure VersiCharge to wall and mounting
bracket with provided screws
3.4 Hard-wired installation
This section describes the hard-wired installation and the removal of the cord and plug
assembly in case the VersiCharge SG units need to be hard-wired during installation.
Removing the Cord-and-Plug Assembly
DANGER Hazardous voltage. Will cause death or serious injury. Turn off power
before working on this equipment by turning the circuit breaker to which this
circuit is wired to the ‘OFF’ position.
Open hinged cover by loosening four cover
Phillips closure screws.
Remove barrier by removing the two securing
screws.
Remove the cord-and-plug assembly from the
conductor opening
o Disconnect the attachment plug wires from
the terminal block by loosening screws in
position 1, 2, and 3.
o Do not adjust the two screws on top of the
terminal block unit. These are for factory use only.
o Disconnect and remove strain relief and entire cord-and-plug
assembly