Installation Guide

28 © 2015 Siemens Industry, Inc. 813776
Halo Deactivation
The Halo indicator on the VersiCharge can be deactivated to marginally lower power
consumption of your device during normal operation. This will prevent the Halo from
illuminating in all states, except the ‘Fault’ state.
To de/re-activate the Halo:
o Remove the coupler from the EV and place in the coupler holster
o Verify that the VersiCharge is in the ‘Power Available’ state by ensuring that only the
‘Power Available’ indicator and, if applicable, the ‘Wi-Fi Status’ indicator LED’s are
illuminated.
o Press and hold both the ‘Pause’ and the ‘Delay Timer’ buttons for 5 seconds. The
Halo will blink green three times, and then fade out to off
4.7 Remote Control Interface
The Siemens VersiCharge has a Remote Control Interface that allows charging to be
controlled by an external device. Examples include demand response switches, building
automation systems, digital sensors, etc.
To wire a digital input into the dry contact in the connection area located inside of the
VersiCharge, please refer to the installation section 3.6 of this manual.
When the external contact is closed, the alternate input will control the VersiCharge,
preventing it from entering the ‘Charging’ state
The status output is a switch that indicates charging status. When the contacts are
closed, the unit is in charging state
4.8 App Operation
Smartphone Application
Installation and setup of the smartphone application is detailed in section 3.7. If you have
not installed the app or linked your charger please review that section and complete the
setup process.
Using your smartphone or tablet, please open the app. You will see the following series
of screens. Log in with the user name and password established in section 3.7. You can
choose to have the app remember your username, if desired.