Technical data
Type selection See Type reference
Mounting position Vertical or horizontal ±5°
Types of gas Gas families II and III
Gas inlet pressure Max. 6 kPa
Operating voltage tolerance Combination gas valve operates correctly
between 85 % and 110 % of rated voltage
Degree of protection IP44 with optional connector
Dimensions Refer to «Dimensions»
Inlet filter No. 100 fine mesh
Pipe connections Refer to «Type code»
Connection for inlet and outlet pressure 9 mm outside dia. tube
Connection for air pressure supply 6.5 mm outside dia. tube
Regulation capacity Min. 0.30 m³/h air
Outlet pressure range 0.05…1.5 kPa
Perm. tightening torque for screws of pres-
sure test points
Max. 2 Nm
Recommendation:
Use a Phillips-head
screwdriver
Valve class
- 1st safety valve
- 2nd safety valve
EN 126
Class B
Class C
Class of regulator Class B to EN 126
Closing time of safety shutoff valves Within 1 s
Maximum pressure difference with closed
shut-off valve
Gas outlet pressure minus air signal
±1.2 kPa
Capacity in m³/h air at pressure drop flow
rate at pressure drop of 0.5 kPa
3.6 m³/h air
Weight
A
pprox. 640 g
Safety shutoff valves Molex contact 3003 Molex, suitable for
female Molex series 3001
Power consumption and current:
Type Pin
connection
1
st
and 2
nd
shut off valve
Supply
voltage
Power
consumption
Current
VGUxxS.A… 1 230 VAC 12 VA 52 mA
VGUxxS.C… 0 230 VRAC 12 VA 52 mA
VGUxxS.H… 0 24 VDC 12 VA 500 mA
VGUxxS.K... 0 120 VRAC 12 VA 100 mA
General unit data
Electrical connections
Electrical data