Operation Manual

73
F
irst check that the nozzle, suction pipe and flexible
h
ose are not blocked, as this would also lead to the
dust bag change indicator being triggered.
The hand grip can easily be detached from the hose
to remove blockages.
Figure Opening the lid
a
)Unlock the lid by pulling on the locking lever in the
direction of the arrow.
b)Open the lid in the direction of the arrow.
F
igure
a)Close the dust bag by pulling on the locking tab.
b)Take out the dust bag.
c)Insert a new dust bag.
d)Push the dust bag fully into the holder.
!
Please note: the lid will only close if a dust bag has
been inserted.
Cleaning the motor protection filter
The motor protection filter should be cleaned regularly
by knocking out the dirt and rinsing.
Figure
Open the dust bag compartment lid.
Figure
a)Release the motor protection filter from the catch by
pulling it sideways, and pull it out in the direction of
the arrow.
b)Clean the motor protection filter by tapping out the
dirt.
c)If it is very dirty, the motor protection filter should be
rinsed.
The filter must then be left to dry for at least 24
hours.
d)After cleaning, refit the motor protection filter into
the appliance, lock it in place and close the dust bag
compartment lid.
Replacing the exhaust filter
Vacuum cleaner with micro-hygiene filter
This should be replaced with every replacement filter
pack
Figure
Open the dust bag compartment lid.
Figure
a)Release the filter holder by moving the locking lever
in the direction of the arrow.
b)Remove the micro-hygiene filter.
c)The micro-hygiene filter can be rinsed out.
The filter must then be left to dry for at least 24
hours.
d)Remove the micro-hygiene filter. Insert the new
micro-hygiene filter into the appliance.
e)Insert the filter holder into the appliance and lock it
in place.
21
22*
19
19
19
2
0
Vacuum cleaner with HEPA filter
If your vacuum cleaner is equipped with a HEPA filter,
this must be replaced once a year.
Figure
Open the dust bag compartment lid.
Figure
a
)Unlock the HEPA filter by moving the locking lever in
the direction of the arrow and remove the filter from
the appliance.
b)Insert the new HEPA filter and lock it in place.
After vacuuming fine dust particles, clean the motor
p
rotection filter and, if necessary, replace the
microhygiene filter or HEPA filter.
Care
Always switch off the vacuum cleaner and disconnect it
from the mains before cleaning the vacuum cleaner. The
vacuum cleaner and plastic accessories can be cleaned
with ordinary plastic cleaner.
!
Do not use abrasive materials, glass-cleaning agents
or all-purpose cleaning products. Never immerse the
vacuum cleaner in water.
If required, the dust compartment can be vacuumed out
with a second vacuum cleaner or simply with a dry
duster/ dusting brush.
Subject to technical modifications.
23*
1
9
*
depending on model
GA 9000 849 148_Z 41 11.12.2012 13:45 Seite 73