Use & Care Guide
Siemens / Speedfax Previous folio: 1-10
Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog
1-10
1
LOAD CENTERS &
CIRCUIT BREAKERS
Discount Schedule RESI
EQ
®
Load Centers
Circuit Breakers Enclosures
Selection/Wiring Diagrams
Breaker Used Indoor Enclosure — NEMA Type 1 Outdoor Enclosure — NEMA Type 3R
Frame Ampere No. of Catalog List Std. Dimensions (inches) Catalog List Std. Dimensions (inches)
Type Rating Poles Number Price $ Pkg. Height Width Depth Number Price $ Pkg. Height Width Depth
1-Phase, 3-Wire SN — 120/240 Volts AC
60 2 E0204ML1060S
햲
76.00 5 9 7/8 5 1/8 2 5/8 W0204ML1060
햲
141.00 5 18 15 4 1/4
QP, QPH, 60 2 E0204ML1060F
햵
116.00 5 9 7/8 5 1/8 2 5/8 ———— — —
HQP 100 2 E0202MB1100 306.00 1 17 1/8 7 3/8 4 5/16 W0202MB1100CU
햵
364.00 1 17.4 7.3 4.3
125 E0204ML1125SCU 121.00 1 17 1/8 7 1/8 4 1/4 W0204ML1125CU 189.00 1 17 1/8 17 3/8 4 5/16
QN, QNH, 200 2 —
— ————W0202ML1200CU 468.00 1 19 3/4 18.4 4.6
HQN 200 2 E0202MB1200 718.00 — 19 3/8 8 1/2 4 W0202MB1200CU
햵
902.00 1 19 3/4 18.4 4.6
QPP, QPPH,
225 1-4 ——————W0406ML1225CU
햳
396.00 1 23 10 4 1/8
HQPP, QP
QJ2, 150 2 ——————WB2150B
햶
949.00 12717 3/8 4 15/16
QJH2, 200 2 ——————WB2200B
햶
949.00 12717 3/8 4 15/16
QJ2-H 225 2 ——————WB2225
햳
418.00 12717 3/8 4 5/16
3-Phase, 3-Wire 240 Volts AC or 3-Phase, 4-Wire SN — 120/208 Volts AC, 120/240, 240 Volts AC
QP, QPH,HQP 100 2-3 E0303ML3100S
햴
189.00 1 17 1/8 7 1/8 4 1/4 W0303ML3100
햴
249.00 1 17 1/8 17 3/8 4 5/16
BQ, BQH, HBQ 100 2-3 EB3100S
햴
189.00 1 17 1/8 7 1/8 4 1/4 WB3100
햴
249.00 1 17 1/8 17 3/8 4 5/16
QJ2, QJH2,
225 2-3 EB3225F
햳
226.00 127111 10 1/8 5 1/8 WB3225
햳
459.00 1 27 10 1/8 5 9/16
QJ2-H
햲
Will not accommodate 2-pole GFCI or circuit breaker with
shunt trip.
햳
42,000A IR maximum. Copper wire only at 225A.
햴
Will not accommodate GFCI or circuit breaker with shunt
trip.
햵
Main breaker factory installed.
햶
QJ2 frame circuit breaker installed, rated 10,000A IR.
Features
▪
Circuit breaker enclosures range from 60A to
225A, indoor and outdoor models
▪
Designed for use exclusively with QP, QT,
QPH, HQP, BQ, BQH, HBQ, QPP, QPPH,
HQPP, QJ2, QJH2 and QJ2-H circuit breakers
▪
UL listed
▪
Suitable for use as service entrance
equipment
▪
UL listed for 60/75°C conductors
(See equipment markings for applications)
Wiring Diagrams
1-Phase, 3-Wire
3-Phase, 4-Wire
E0204ML1060
W0204ML1060
1 or 2-Poles
E0204ML1125FCU
W0204ML1125CU
1 or 2-Poles
WB2225
One 2-Pole
W0406ML1225CU
1 or 2-Poles
E0303ML3100CU
EB3100
W0303ML3100CU
WB3100
EB3225
WB3225
2 or 3-Pole
W0202MB1200CU E0303ML3100CU
NEW
NEW
Sect_01_Speedfax2007 10/9/07 10:18 AM Page 1-10
• Revised •
12/21/2007