User's Manual

Configuration Using Web Based Management and the Command Line Interface
Syntax of the Command Line Interface
CLI\IFEATURES\REDUNDANCY>
Command Description Comment
redun <E|D>
Enables / disables the redundancy
function
wep <E|D>
Enables / disables WEP encryption.
mac1 <MAC address>
Specifies the device that will be op-
erated redundantly along with the
first wireless adapter.
mac2 <MAC address>
Specifies the device that will be op-
erated redundantly along with the
second wireless adapter.
wepkey1
Specifies the WEP key of the device
that will be operated redundantly
along with the first wireless adapter.
wepkey2
Specifies the WEP key of the device
that will be operated redundantly
along with the second wireless
adapter.
6.7.4 IP-Alive Menu Command
Application-Related Connection Monitoring
The IP-Alive function provides application-related connection monitoring of the
wireless link.
With IP-Alive, you specify a monitoring time for an IP address and a port. In con-
trast to the Link Check, the SCALANCE W 788 does not start any checks until the
monitoring time has elapsed. In contrast to the Link Check, the SCALANCE W 788
does not actively monitor the connection. The SCALANCE W 788 checks passively
whether communication took place during the specified monitoring period.
System Event for Connection Abort
You can specify how the SCALANCE W 788 reacts to change in the IP-Alive status
in the System > Event Config menu.
Operating Instructions SCALANCE W 788-1pro / SCALANCE W 788-2pro
102 C79000-G8976-C184-01