User's Manual

Configuration Using Web Based Management and the Command Line Interface
If you want to deactivate the option of configuration with Web Based Management,
you can do this in the Security Wizard. Any settings you make there only take ef-
fect after you restart the SCALANCE W 788.
Syntax of the Command Line Interface
CLI\SYSTEM\SERVICES>
Command Description Comment
telnet <E|D>
Enable / disable configuration of the
SCALANCE W 788 over Telnet.
ttimeout <E|D>
Enables / disables the time restric-
tion for a Telnet session.
ttimeout <time in s>
Specifies the time after which a Tel-
net section is closed if there is no
further input.
web <E|D>
Enable / disable configuration of the
SCALANCE W 788 over Web Based
Management.
snmp <E | D>
Enable / disable SNMP.
psu <E|D>
Enable / disable access to the
SCALANCE W 788 with the Primary
Setup Tool. If this access option is
deactivated, configuration data can
only be read with the Primary Setup
Tool.
Operating Instructions SCALANCE W 788-1pro / SCALANCE W 788-2pro
C79000-G8976-C184-01