User's Manual
Configuration Using Web Based Management and the Command Line Interface
There is no automatic restart. This allows you to enter data using Web Based Man-
agement before the restart. The changes take effect only after a restart.
In User mode, this button is not visible.
Reset to memory defaults and restart Button
Click on this button to restore the factory configuration settings. The protected de-
faults (see above) are also reset. An automatic restart is triggered.
Note
By resetting all the defaults, the IP address is also lost. The SCALANCE W 788
can then only be accessed using the Primary Setup Tool unless the IP address is
obtained over DHCP.
In User mode, this button is not visible.
Syntax of the Command Line Interface
CLI\SYSTEM\RESTARTS>
Command Description Comment
restart
Restarts the SCALANCE W 788. The restart command can
be invoked in all menus.
memreset
Resets the factory settings and trig-
gers a restart (the protected settings
are also deleted).
defaults
Resets the factory settings and trig-
gers a restart (the protected settings
are not deleted).
Operating Instructions SCALANCE W 788-1pro / SCALANCE W 788-2pro
C79000-G8976-C184-01
69