User's Manual

Communication
Industrial Ethernet
SCALANCE X Industrial Ethernet switches
9/18
Siemens ST PCS 7 · November 2007
9
Type SCALANCE X212-2 SCALANCE X212-2LD
Transmission rate
10/100 Mbit/s 10/100 Mbit/s
Interfaces
• Communications connection, electrical (see
also table "Summary of interfaces")
12 x RJ45 (10/100 Mbit/s; TP) 12 x RJ45 (10/100 Mbit/s; TP)
• Communications connection, optical (see also
table "Summary of interfaces")
2 x BFOC socket (100 Mbit/s) 2 x BFOC socket (100 Mbit/s)
• Connection for power supply
1 x 4-contact terminal block 1 x 4-contact terminal block
• Connection for signaling contact
1 x 2-contact terminal block 1 x 2-contact terminal block
• Slot for swap medium
C-PLUG C-PLUG
Power supply
2 x 24 V DC (18 to 32 V) 2 x 24V DC (18to32V)
Current consumption
330 mA 330 mA
Power loss at 24 V DC
7.92 W 7.92 W
Network size parameters / TP cable length
•0 to 55 m IE TP Torsion Cable with IE FC RJ45 Plug IE TP Torsion Cable with IE FC RJ45 Plug
IE FC Outlet RJ45 with IE TP Torsion Cable
(0 to 45 m)
+ 10 m TP Cord
IE FC Outlet RJ45 with IE TP Torsion Cable
(0 to 45 m)
+ 10 m TP Cord
•0 to 85 m
IE FC Marine/ Trailing/ Flexible/ FRNC Cable
with IE FC RJ45 Plug
IE FC Marine/ Trailing/ Flexible/ FRNC Cable with
IE FC RJ45 Plug
IE FC Outlet RJ45 with IE FC Marine/
Trailing/Flexible Cable (0 to 75 m) + 10 m TP
Cord
IE FC Outlet RJ45 with IE FC Marine/Trailing/
Flexible Cable (0 to 75 m) + 10 m TP Cord
• 0 to 100 m
IE FC Standard Cable GP with IE FC RJ45
Plug
IE FC Standard Cable GP with IE FC RJ45 Plug
IE FC Outlet RJ45 with
IE FC Standard Cable GP
(0 to 90 m) + 10 m TP Cord
IE FC Outlet RJ45 with
IE FC Standard Cable GP
(0 to 90 m) + 10 m TP Cord
• 0 to 750 m
Glass FOC 62.5/125 µm or 50/125 µm;
1.0 dB/km with 1300 nm; 600 MHz x km
--
• 0 to 3 km
-- Glass FOC or 9/125 µm singlemode fiber;
0.5 dB/km with 1300 nm
•0 to 26 km
IE TP Torsion Cable with IE FC RJ45 Plug IE TP Torsion Cable with IE FC RJ45 Plug
Permissible ambient conditions
• Operating temperature 0 to +60 °C 0 to +60 °C
• Transport/storage temperature
-40 to +80 °C -40 to +80 °C
• Relative humidity during operation
< 95% (no condensation) < 95% (no condensation)
Design
• Dimensions (W x H x D) in mm 120 x 125 x 124 120 x 125 x 124
•Weight
1200 g 1200 g
• Mounting
DIN rail, S7-300 rail, wall mounting DIN rail, S7-300 rail, wall mounting
Degree of protection
IP30 IP30
Approvals
• Radio interference suppression level EN 61000-6-4 Class A EN 61000-6-4 Class A
• Noise immunity
EN 61000-6-2 EN 61000-6-2
•cUL-Listung
UL 60950-1, CSA C22.2 No. 60950-1 UL 60950-1, CSA C22.2 No. 60950-1
•FM
FM 3611 FM 3611
• ATEX Zone 2
EN 50021 EN 50021
•C-Tick
AS/NZS 2064 (Class A) AS/NZS 2064 (Class A)
•CE
EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4
• Shipbuilding approvals
• Lloyds Register of Shipping
• Det Norske Veritas
• Germanischer Lloyd
• Nippon Kaiji Kyokai
• Bureau Veritas
• Lloyds Register of Shipping
• Det Norske Veritas
• Germanischer Lloyd
• Nippon Kaiji Kyokai
• Bureau Veritas