Manual and User Guide
Table Of Contents
- TABLE 1
- Figure 1
- INSTALLATION CODES
- CODES D'INSTALLATION
- TO TURN GAS OFF TO APPLIANCE
- COMMENT COUPER L’ADMISSION DE GAZ
- L’APPAREIL
- The minimum vent system for horizontal termination must consist of:
- The maximum horizontal vent system consists of:
- The minimum vent system for horizontal termination must consist of:
- The maximum horizontal vent system consists of:
- The minimum vent system for horizontal termination must consist of:
- The maximum horizontal vent system consists of:
- The minimum vent system for horizontal termination must consist of:
- The maximum horizontal vent system consists of:
- The minimum vent system for horizontal termination must consist of:
- The maximum horizontal vent system consists of:
- The maximum vertical system consists of:
- Apply RTV high temperature
- sealant around male pipe.
- 3.3.9 PRIMARY AIR ADJUSTMENT / AJUSTEMENT DE L'AIR PRIMAIRE
- CORRECTIVE ACTION
- SYMPTOM
- 1. Weak or improperly located pilot flame
- 2. Defective thermocouple
- 3.Thermocouple not installed properly
- 4. Open wire connection in pilot circuit
- 5. Defective Valve
- 1. Loose or defective connections
- III. Main burner will not light
- 1. Valve control off
- 2. Blockage at the burner (line, orifice, or ports)
- 3. Defective remote
- 4. Defective wiring or connections
- 5. Defective Valve
- I. Soot deposits
- 1. Air inlet blocked or restricted
- 2. Vent system is restricted or inadequate
- 3. Logs are sooting up
- V. Flame burns blue and lifts off burner
- 1. Insufficient combustion air being supplied
- 2. Manifold pressure set too high
- 3. Vent system restricted
- VI. Main flame does not burn properly
- VII. Flames impinge on firebox top
- 1. Vent system is restricted or inadequate
- 2. Manifold pressure too high
- 8.0 LABEL INFORMATION
- WARNING
- Electrical Grounding Instructions
- APPENDIX A (AMERICAN FLAME VALVE INFORMATION)
- APPENDIX A (Continued)
- APPENDIX B (NG – LP CONVERSION KITS)
Page 16 of 54
3.3.1 MINIMUM CLEARANCES / DÉGAGEMENTS
NON-COMBUSTIBLE BOARD – 12" (305mm) x 64.25" (1632mm) WILL BE
SUPPLIED BY MANUFACTURER AND MUST BE ATTACHED TO TOP OF FIREPLACE
SEE DIAGRAM PAGE 18
MINIMUM CLEARANCES TO COMBUSTIBLES
A = 58”
TO INTERNAL CEILING
B = 3.5”
TO INTERNAL BACK COMBUSTIBLES
C = 17.5”
TO BACK WALL FROM FRONT OF UNIT
D = 6”
FROM EDGE OF FIREPLACE TO SIDE WALL
E = 39”
FROM BOTTOM OF FIREPLACE TO STEEL STUD
F = 2”
TO INTERNAL SIDE COMBUSTIBLES
G=45”
MINIMUM FROM BOTTOM OF FIREPLACE TO MANTLE
(SEE DIAGRAM NEXT PAGE)
0”
BASE OF UNIT TO FLOOR
A
B
C
D
E
F
G