- The minimum vent system for horizontal termination must consist of:
- The maximum horizontal vent system consists of:
- The minimum vent system for horizontal termination must consist of:
- The maximum horizontal vent system consists of:
- The minimum vent system for horizontal termination must consist of:
- The maximum horizontal vent system consists of:
- The minimum vent system for horizontal termination must consist of:
- The maximum horizontal vent system consists of:
- The minimum vent system for horizontal termination must consist of:
- The maximum horizontal vent system consists of:
- The maximum vertical system consists of:
- Apply RTV high temperature
- sealant around male pipe.
- 3.3.9 PRIMARY AIR ADJUSTMENT / AJUSTEMENT DE L'AIR PRIMAIRE
- CORRECTIVE ACTION
- SYMPTOM
- 1. Weak or improperly located pilot flame
- 2. Defective thermocouple
- 3.Thermocouple not installed properly
- 4. Open wire connection in pilot circuit
- 5. Defective Valve
- 1. Loose or defective connections
- III. Main burner will not light
- 1. Valve control off
- 2. Blockage at the burner (line, orifice, or ports)
- 3. Defective remote
- 4. Defective wiring or connections
- 5. Defective Valve
- I. Soot deposits
- 1. Air inlet blocked or restricted
- 2. Vent system is restricted or inadequate
- 3. Logs are sooting up
- V. Flame burns blue and lifts off burner
- 1. Insufficient combustion air being supplied
- 2. Manifold pressure set too high
- 3. Vent system restricted
- VI. Main flame does not burn properly
- VII. Flames impinge on firebox top
- 1. Vent system is restricted or inadequate
- 2. Manifold pressure too high
- 8.0 LABEL INFORMATION
- WARNING
- Electrical Grounding Instructions
- APPENDIX A (AMERICAN FLAME VALVE INFORMATION)
- APPENDIX A (Continued)
- APPENDIX B (NG – LP CONVERSION KITS)
Page 18 of 54
The closest combustible material above the fireplace must be a minimum of 40.00” from the floor with the steel
stud laying on edge as shown above. / Le matériau combustible le plus proche dessus de la cheminée doit être
un minimum de 40,00 "de l'étage avec le goujon en acier portant sur le bord comme indiqué ci-dessus.
NON COMBUSTIBLE MATERIAL/ MATIERE NON COMBUSTIBLES
Non-combustible material will be supplied by the manufacturer. This must be installed on top of the fireplace as
shown above to meet installation codes.
Matériaux non combustibles seront fournis par le fabricant. Ce doit être installé sur le dessus du foyer, comme
indiqué ci-dessus pour répondre aux codes d'installation.
40.00 TO TOP OF
NON- COMBUSTIBLE
BOARD FROM
BOTTOM OF
FIREPLACE
39.00 TO
BOTTOM
OF
STEEL
STUD ON
EDGE
STEEL STUD
NON-COMBUSTIBLE
BOARD 12 X 64.25
SUPPLIED BY
MANUFACTURER
68.38