Manual and User Guide
Table Of Contents
- TABLE 1
- Figure 1
- INSTALLATION CODES
- CODES D'INSTALLATION
- TO TURN GAS OFF TO APPLIANCE
- COMMENT COUPER L’ADMISSION DE GAZ
- L’APPAREIL
- The minimum vent system for horizontal termination must consist of:
- The maximum horizontal vent system consists of:
- The minimum vent system for horizontal termination must consist of:
- The maximum horizontal vent system consists of:
- The minimum vent system for horizontal termination must consist of:
- The maximum horizontal vent system consists of:
- The minimum vent system for horizontal termination must consist of:
- The maximum horizontal vent system consists of:
- The minimum vent system for horizontal termination must consist of:
- The maximum horizontal vent system consists of:
- The maximum vertical system consists of:
- Apply RTV high temperature
- sealant around male pipe.
- 3.3.9 PRIMARY AIR ADJUSTMENT / AJUSTEMENT DE L'AIR PRIMAIRE
- CORRECTIVE ACTION
- SYMPTOM
- 1. Weak or improperly located pilot flame
- 2. Defective thermocouple
- 3.Thermocouple not installed properly
- 4. Open wire connection in pilot circuit
- 5. Defective Valve
- 1. Loose or defective connections
- III. Main burner will not light
- 1. Valve control off
- 2. Blockage at the burner (line, orifice, or ports)
- 3. Defective remote
- 4. Defective wiring or connections
- 5. Defective Valve
- I. Soot deposits
- 1. Air inlet blocked or restricted
- 2. Vent system is restricted or inadequate
- 3. Logs are sooting up
- V. Flame burns blue and lifts off burner
- 1. Insufficient combustion air being supplied
- 2. Manifold pressure set too high
- 3. Vent system restricted
- VI. Main flame does not burn properly
- VII. Flames impinge on firebox top
- 1. Vent system is restricted or inadequate
- 2. Manifold pressure too high
- 8.0 LABEL INFORMATION
- WARNING
- Electrical Grounding Instructions
- APPENDIX A (AMERICAN FLAME VALVE INFORMATION)
- APPENDIX A (Continued)
- APPENDIX B (NG – LP CONVERSION KITS)
Page 43 of 54
6.0 REPLACEMENT PARTS
When requesting service or replacement parts for your unit, please provide model name and serial
number. All parts listed below may be ordered from an authorized dealer.
Description Part# Certification
Door 2126 N/A
Burner Left 2108L N/A
Burner Right 2108R N/A
Fan IMC1057A CSA / UL
Door Glass 2145 ASTM C1048
Restrictor 2158 N/A
Door Glass Gasket 6AL N/A
Safety Screen PINN55SC N/A
Orifice - NG MP0505-45 (x2) N/A
Orifice – LP MP0505-56 (x2) N/A
Propane Conversion Kit LPCKLCF65 CSA C & US
Natural Gas Conversion Kit NGCKLCF65 CSA C & US
Intermittent Pilot & Remote Control Valve Parts
Description Part#
Pilot Assembly (Intermittent) PSE-NA291 CSA / UL
Valve AF-40004 CSA C & US
Valve (with step motor installed) AF-4044 CSA C & US
Remote Step Motor for AF-4000 Valve AF-4000MOT CSA C & US
Supreme Control Module, incl.wire harness AF-4000MOD-S01 CSA C & US
Plug-in Adapter ((7.5V A/C & 24” wires) AF-4000ADP24 CSA C & US
Battery Back-up AF-4000BBU CSA C & US
Extension Module for 120V operation AF-4000120MODS01 CSA C & US
Supreme Handheld transmitter AF-4000HHS01 CSA C & US