ELECTRIC FIREPLACES SAFETY INFORMATION AND INSTALLATION MANUAL INS-FM-30 INS-FM-34 ZC-FM-37 ZC-FM-45 Read these instructions completely before beginning installation. Failure to follow them could cause a heater malfunction and result in serious injury and/or property damage. WARNING: All electric heaters have hot or sparking parts inside. Do not use it in areas where gasoline, paint or flammable liquids are stored.
TABLE OF CONTENTS CONGRATULATIONS! In selecting this Sierra Flame Wall Mount OR Built-in electric fireplace, you have chosen the finest and most dependable fireplace on the market today. A beautiful and functional addition to the finest homes. Welcome to the family of satisfied Sierra Flame electric fireplace owners. Please read and carefully follow all of the instructions found in this manual. Please pay special attention to the safety instructions provided in this manual.
Keep this manual for future reference. SAFETY INFORMATION Due to high temperatures, the insert should be located out of traffic and away from furniture and draperies. Do not place clothing or other flammable material on or near the insert. Never place any objects on the insert. The insert can become very hot when running. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. The insert will remain hot for a time after shutdown. Allow surfaces to cool before touching.
12. Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons. 13. Avoid the use of an extension cord because the extension cord may overheat and cause a fire. If you have to use an extension cord, the cord should be No. 14 AWG minimum size and rated not less than 1875 WATTS. 14. Always use a properly grounded, protected (fuse or circuit breaker), and polarized outlet. 15.
INS-FM-30 INS-FM-3 Description Voltage Amps Watts Built-in Appliance 120V AC, 60 Hz 12A 1500 W HIGH 1500W HEATER LOW 750W No HEATER 18W Motor HEATER 30W Motor Flame 4W Appliance Width 38" or 96.5 cm Appliance Height 24 7/8" or 63.3cm Appliance Depth 8 1/2" or 21.58 cm Gross Weight 63.93 Lbs or 29 Kg Plug Location Left side Cord Length 74 3/4" or 190 cm Rough Wall Opening Size 31 1/4"x19 5/8" or 79.5 cmx49.
INS-FM-34 Description Voltage Amps Watts Built-in Appliance 120V AC, 60 Hz 12A 1500 W HIGH 1500W HEATER LOW 750W No HEATER 18.5W Motor HEATER 30W Motor Flame 4W Appliance Width 42" or 106.8 cm Appliance Height 30" or 76.2 cm Appliance Depth 8 1/2" or 21.58 cm Gross Weight 72.75 Lbs or 33 Kg Plug Location Left side Cord Length 74 3/4" or 190 cm Rough Wall Opening Size 32 7/8" x 23 5/8" or 83.
ZC-FM-37 Description Voltage Amps Watts Built-in Appliance 120V AC, 60 Hz 12A 1500 W HIGH 1500W HEATER LOW 750W No HEATER 19W Motor HEATER 30W Motor Flame 4W Appliance Width 37" or 93.98 cm Appliance Height 27 1/2" or 69.9 cm Appliance Depth 8 1/2" or 21.58 cm Gross Weight 66.13 Lbs or 30 Kg Plug Location Left side Cord Length 74 3/4" or 190 cm Rough Wall Opening Size 31 1/4"x25 1/4" or 79.5 cmx64.
ZC-FM-45 Description Voltage Amps Watts Built-in Appliance 120V AC, 60 Hz 12A 1500 W HIGH 1500W HEATER LOW 750W No HEATER 20W Motor HEATER 30W Motor Flame 4W Appliance Width 45" or 114.36 cm Appliance Height 34 5/8" or 87.8 cm Appliance Depth 8 1/2" or 21.58 cm Gross Weight 94.8 Lbs or 43 Kg Plug Location Left side Cord Length 74 3/4" or 190 cm Rough Wall Opening Size 39 1/2"x32 3/8" or 100.3 cmx82.
LOCATING THE FIREPLACE INSERT WARNING: Never locate this heater where it may fall into a bathtub or any water container. NOTICE: All clearances must be maintained to combustibles. Illustrations throughout these instructions reflect typical installations and are for design purposes only. Actual installations may vary slightly due to individual preferences. Heater must be placed so it remains level (use included level to verify).
CLEARANCES WHEN BUILT-IN MANTEL(maximum 12" (305mm) deep WALL MINIMUM 3/8" (10mm) CLEARANCE TO TOP 2"[50.8 mm] OF APPLIANCE( combustible or non-combustible) FRONT GLASS APPLIANCE SIDE VIEW MINIMUM 1" (25.4mm) CLEARANCE TO SIDES AND BACK OF APPLIANCE (combustible or non-combustible) FLOOR The fireplace insert may be placed within a framed enclosure that is level, dry, and capable of supporting the weight of the appliance and front glass.
UNPACKING AND TESTING THE FIREPLACE INSERT Carefully remove the fireplace insert from the box. Remove the packing screws from both sides of the insert (see illustration to the right). Prior to installing the fireplace insert, plug the unit into a 120-volt grounded outlet and test operation. Test all aspects of its operation (manual switches, remote, display characteristics and heater) to make sure all components operate correctly.
INSTALLATION OVERVIEW – MASONRY FIREPLACES Cover plate is required if chimney does not have suitable rain cap. one Silic 2” (50mm) Minimum HINT: Close and seal the damper to prevent air infiltration. Attach the "This fireplace has been altered..." plate to the fireplace (use two screws or other suitable method). You may wish to place it in a location where it will be covered by the surround glass.
INSTALLATION OVERVIEW – ZERO-CLEARANCE (METAL) FIREPLACES Cover plate is required if chimney does not have suitable rain cap. one Silic The log shelf, screen, and doors (if present) must be removed. 2” (50mm) Minimum HINT: Close and seal the damper to prevent air infiltration. HINT: Paint the interior of the fireplace with latex paint to prevent fireplace odors from entering the home. Attach the "This fireplace has been altered..." plate to the fireplace (use two screws or other suitable method).
OPERATING INSTRUCTIONS REMOVING THE SURROUND GLASS Before removing the surround glass, make sure to have a suitable location to place the surround glass once it is removed. Do not place the glass on sharp or uneven areas that may chip or damage the tempered glass. Use both hands to lift the surround glass directly up. The hooks on the glass will disengage from the pins that protrude from the side of the insert.
REMOTE CONTROL OPERATION The button located at the top position of the remote control is ON/OFF. Press it, the flame and ember will be on. The heater will be off. Press again, the fireplace will turn off. “DISPLAY ON/OFF”: Switching the fireplace flame and tray light ON/OFF. It has functions of setting memory. “FLAME ORANGE”: Adjust the orange colour brightness of flame. “FLAME YELLOW”: Adjust the yellow colour brightness of flame. “TRAY ORANGE”: Adjust the orange colour brightness of tray.
DIRECT OPERATION 1. Power ON/OFF switch 2. Heat control button 3. Flame control button 4. HEATER LED 5. POWER LED Plug the heater into a suitable outlet. 1) “Power ON/OFF” Set this switch to position I to turn the product ON. Setting it to O to turn the product OFF. POWER LED will be lit when the fireplace insert is on. The 2) “Heat control button” Press the HEAT button repeatedly to set the heater to the desired heat set.
CLEANING AND MAINTENANCE WARNING: Always disconnect the power and allow the heater to cool before performing any cleaning, maintenance or relocation. Turn the controls to OFF and remove the plug from the outlet or turn off the circuit breaker before attempting any cleaning. FRONT GLASS 1. Remove dust by buffing lightly with a clean dry cloth. 2. To remove fingerprints or other marks, the glass can be cleaned with a damp cloth using a good quality household glass cleaner.
REPLACEMENT PARTS REF NO PART NO.
TROUBLE SHOOTING WARNING: Always disconnect power and allow the heater to cool before performing any cleaning, maintenance or relocation. Turn the controls to OFF and remove the plug from the outlet or turn off the circuit breaker before attempting any cleaning.
Exploded View 19
SERVICE HISTORY 20
WARRANTY Sierra Flame Imports Corp. (” Sierra Flame”) warrants that your newly purchased Sierra Flame electric fireplace is free from manufacturing and material defects for a period of one (1) year from the date of the first purchase, subject to the conditions and limitations contained below.
employees, consultants, agents, heirs, executors, administrators and assigns, have been advised of the possibility of such losses, costs or damages, or if such losses, costs or damages are foreseeable. In no event will Sierra Flame, including without limitation any of its directors, officers, shareholders, employees, consultants, agents, heirs, executors, administrators and assigns, be liable for any direct losses, costs or damages that exceed the purchase price of the product.
Date of Purchase: Dealer Information: