User guide

ALEOS User Guide
120 20080616
Configuration
To enhance the usability of the I/O, the configuration will allow you to set an initial
value for the output relays and a coefficient, offset, and unit label for the analog in.
Figure 13-2: ACEmanager: IO - Configuration
Table 13-1: I/O
Command Description
Digital IN # Query individual digital inputs. The digital inputs report either a 0 (open) or 1 (closed).
n=1-4 Input number
Pulse Count On devices with a digital input that can be configured for use as a digital output, the pulse
counts will also reflect output changes.
*ANALOGIN # Query individual analog inputs. The analog inputs report the voltage in volts.
n=1-4 Input number
Transformed
Analog #
Trasnformed Analog is derived from your coefficient and raw analog.
For example, if your Analog In1 is 2 and Coefficient is 4, with an Offset setting of 2
(definition as below), the Transformed Analog will be 10.
Relay Output # Set or query the relay outputs.
n=1-2 Input number
s=OPEN or CLOSED