User guide

WA_DEV_GL6100_PTS_001 Rev 004 November 30, 2010 16
GL61x0 Product Technical
Specification and User Guide
GL61x0 Feature Set
Features
Description
Others
Real Time Clock with calendar
2.1. Supported Bands
The GL61x0 supports either EU bands (EGSM900/DCS1800) or US bands (GSM850/PCS1900).
Users may switch from one supported band to another using AT commands.
Refer to sections 8.4 Checking the Band Selection and 8.5 Switching Bands for more information
regarding switching bands.
2.2. Protection
2.2.1. Power Supply
2.2.1.1. GL6100 UART Version
The GL6100 is protected against voltage over +32V. When the input voltage (Vin) exceeds the limit,
the supply voltage is disconnected to protect the internal electronic components from overvoltage.
Note: An 800mA/250V fuse is directly bonded on the Adaptive cable of GL6100. The fuse model is FSD
800mA/250V FAST-ACTING.
Figure 2. Adaptive Cable Fuse
2.2.1.2. GL6110 USB Version
The GL6110 is protected against voltage over +5V. When the input voltage (Vin) exceeds the limit,
the supply voltage is disconnected to protect the internal electronic components from overvoltage.