User guide

WA_DEV_GL6100_PTS_001 Rev 002 May 24, 2010 73
GL61x0 Product Technical
Specification and User Guide
Reliability Standards: Compliance and
Recommendations
Designation
Condition
TSKT
Special conditions:
Upper temperature: +85°C
Lower temperature: -40°C
Rate of temperature change: 30s
Number of cycles: 200
Duration of exposure: 30 minutes
Recovery time: 3 hours
Operating conditions: Un-powered
Duration: 72 hours
13.4.5. Mechanical Resistance Stress Tests
The following tests the GL61x0s resistance to vibrations and mechanical shocks.
Table 59: Mechanical Resistance Stress Tests
Designation
Condition
Sinusoidal Vibration Test
SVT
Standard: IEC 60068-2-6, Test Fc
Special conditions:
Frequency range: 10Hz to 1000Hz
Displacement: ±5mm (peak)
Frequency range: 16Hz to 62Hz
Acceleration: 5G
Frequency range: 62Hz to 200Hz
Acceleration: 3G
Frequency range: 200Hz to 1000Hz
Acceleration: 1G
Sweep rate: 1 oct/min.
Test duration: 20 cycles
Sweep directions: X, Y and Z
Operating conditions: Un-powered
Duration: 72 hours
Random Vibration Test
RVT
Standard: IEC 60068-2-64
Special conditions:
Density spectrum: 0.96/s3
Frequency range:
0.1 g
2
/Hz at 10Hz
0.01 g
2
/Hz at 250Hz
0.0005 g
2
/Hz at 1000Hz
0.0005 g
2
/Hz at 2000Hz
Slope: -3dB/octave
Acceleration: 0.9gRMS
Number of axis: 3
Operating conditions: Un-powered