WA_DEV_GL6100_PTS_001 Rev 002 May 24, 2010 74
GL61x0 Product Technical
Specification and User Guide
Reliability Standards: Compliance and
Recommendations
Designation
Condition
Duration: 16 hours
Mechanical Shock Test
MST
Standard: IEC 60068-2-27, Test Ea
Special conditions:
Shock Test 1:
Wave form: Half sine
Peak acceleration: 30G
Duration: 11ms
Number of shocks: 8 per direction
Number of directions: 6 (±X, ±Y, ±Z)
Shock Test 2:
Wave form: Half sine
Peak acceleration: 200G
Duration: 3ms
Number of shocks: 3 per direction
Number of directions: 6 (±X, ±Y, ±Z)
Shock Test 3:
Wave form: Half sine
Peak acceleration: 100G
Duration: 6ms
Number of shocks: 3 per direction
Number of directions: 6 (±X, ±Y, ±Z)
Operating conditions: Un-powered
Duration: 72 hours
13.4.6. Handling Resistance Stress Tests
The following tests the GL61x0s resistance to handling malfunctions and damages.
Table 60: Handling Resistance Stress Tests
Designation
Condition
ESD Test
Standard: IEC 1000-4-2
Special conditions:
Contact discharges: 10 positive and 10 negative applied
Voltage: ±2kV, ±4kV, ±6kV
Operating conditions: Powered
Duration: 24 hours
Operational Durability
Standard : N/A