AirPrime and HL7548 AT Commands Interface Guide Rev10 0

Table Of Contents
4116303 Rev 10.0 August 10, 2017 104
AT Commands Interface Guide
Mobile Equipment Control and Status
Commands
HL7518 and HL7548
95 -46 dBm ≤ rsrp < -45 dBm
96 -45 dBm ≤ rsrp < -44 dBm
97 -44 dBm ≤ rsrp
255 Not known or not detectable
<rssnr> Integer type; radio signal strength noise ration value
-100 RSSNR ≤ -50 dB
-99 -50 dB < RSSNR ≤ -49.5 dB
-98 -49.5 dB < RSSNR ≤ -49 dB
-1 -1 dB < RSSNR ≤ -0.5 dB
0 -0.5 dB < RSSNR ≤ 0 dB
1 0 dB < RSSNR ≤ 0.5 dB
98 49 dB ≤ RSSNR < 49.5 dB
99 49.5 dB ≤ RSSNR < 50 dB
100 50 dB ≤ RSSNR
255 Not known or not detectable
Unsolicited
Notification
Response
+XCESQI: <rxlev>,<ber>,<rscp>,<ecno>,<rsrq>,<rsrp>,<rssnr>
Notes
If the current serving cell is not a GERAN cell, <rxlev> and <ber> are set to value
99.
If the current serving cell is not a UTRA FDD or UTRA TDD cell, <rscp> and
<ecno> are set to 255.
If the current serving cell is not an E-UTRA cell, <rsrq>, <rsrp> and <rssnr> are set
to 255.
5.48. +CPWROFF Command: Switch MS Off
HL7518 and HL7548
Test command
Syntax
AT+CPWROFF=?
Response
OK
Execute/Write
command
Syntax
For HL7518:
AT+CPWROFF
For HL7548:
AT+CPWROFF
[=<mode>]
Response
OK
or
+CME ERROR: <error>
Parameter
<mode> Power down mode. This parameter is only available in the HL7548.
1 Fast power down mode
Notes
Not specifying a parameter value for the execute command will perform normal
IMSI detach before powering down.
<mode>=1 will perform fast power down without an IMSI detach request being sent
to the network (~1s faster than power down mode).