AirPrime and HL7548 AT Commands Interface Guide Rev10 0

Table Of Contents
4116303 Rev 10.0 August 10, 2017 197
AT Commands Interface Guide
Protocol Specific Commands
11.7.5. +KCNX_IND Notification: Connection Status
Notification
HL7518 and HL7548
Unsolicited
Notification
Response
+KCNX_IND: <cnx cnf>,<status>,<af> (for <status> = 0, 1)
+KCNX_IND: <cnx cnf>,<status>,<attempt>,<nbtrial>,<tim1> (for <status> = 2)
+KCNX_IND: <cnx cnf>,<status> (for <status> = 3, 6)
+KCNX_IND: <cnx cnf>,<status>,<attempt> (for <status> = 4)
+KCNX_IND: <cnx cnf>,<status>,<idletime> (for <status> = 5)
Parameters
<cnx cnf> 1 – 5 (PDP context configuration) a numeric parameter which specifies a
particular PDP context configuration
<status> PDP connection status
0 Disconnected due to network
1 Connected
2 Failed to connect, <tim1> timer is started if <attempt> is less than <nbtrail>
3 Closed
4 Connecting
5 Idle time down counting started for disconnection
6 Idle time down counting canceled
<af> 0 IPV4
1 IPV6
<tim1> Refer to +KCNXTIMER
<attempt> Current attempt of bringing up of PDP connection
<nbtrial> Refer to +KCNXTIMER
<idletime> Refer to +KCNXTIMER
Reference
Sierra Wireless
Proprietary
11.7.6. +KCNXUP Command: Bring the PDP Connection
Up
HL7518 and HL7548
Test command
Syntax
AT+KCNXUP=?
Response
+KCNXUP: (list of possible <cnx_cnf>s)
OK