Rectangular areas can be set to display the Maximum, Mean or Minimum
temperatures. Press the M Key to bring up the main menu, then press the Key to
highlight and select the Setup option, then select “Analysis” by pressing the M or OK
Keys.
Under the heading named “Area”, you can toggle between “Min”, “Mean” and “Max”
by pressing the
or
Keys and confirm the selection by pressing the M or OK
Keys.
It is possible to toggle between one and four measurement areas. Choose the
heading named “Mul Spot/Area” and toggle between “on” and “off” by pressing the
or
Keys, then confirm the selection by pressing the M Key. Note, only one area is
present in the “off” position.
Press the C Key to exit and return to the saved image.
Note:
Pressing the
switches between two modes, for changing area location
and for adjusting area size. Under each mode, pressing the
will switch
back to the other.
The beginning size of the rectangular temperature measurement areas
displayed is the minimum size available and cannot be reduced by the
operator.
Isotherm Sub-menu
The Isotherm procedure can be performed on live, captured and saved images.
Press the M or Keys to enter the “Analysis” menu. Press the Key to highlight
and select “Isotherm”, then confirm the selection by pressing the M or OK Keys.