User Manual
Table Of Contents
- Copyright and Declaration
- Safety Information
- L'information de sûreté
- Document Overview
- Quick Start
- Vertical System
- Horizontal System
- Sample System
- Trigger
- Serial Trigger and Decode
- Reference Waveform
- Math
- Cursors
- Measure
- Display
- Save and Recall
- Digital Channels(Option)
- System Setting
- Bode Plot II
- Search
- Navigate
- History
- Factory Setup
- Troubleshooting
SDS1000X-E User Manual
133
WWW.SIGLENT.COM
Type of Measurement
Voltage Measurements
Voltage measurements include 15 kinds of voltage parameter measurements.
Figure 84 Voltage Measurements
1.
Peak-Peak:
Difference between maximum and minimum data values.
2.
Maximum:
Highest value in input waveform.
3.
Minimum:
Lowest value in input waveform.
4.
Amplitude:
Difference between top and base in a bimodal signal, or between max and
min in an unimodal signal.
5.
Top:
Value of most probable higher state in a bimodal waveform.
6.
Base:
Value of most probable lower state in a bimodal waveform.
7.
Mean:
Average of all data values
8.
Cycle mean:
Average of data values in the first cycle.
9.
Stdev:
Standard deviation of all data values
10.
Cycle Stdev:
Standard deviation of all data values in the first cycle
11.
Rms:
Root mean square of all data values.
12.
Cycle RMS:
Root mean square of all data values in the first cycle.
13.
Overshoot:
Overshoot is distortion that follows a major edge transition expressed as a
percentage of Amplitude. ROV means rising edge overshoot and FOV means falling
edge overshoot.