Data Sheet

SDG1000 Series DataSheet
7
PWM Modulation(CH1/CH2)
Frequency 500μHz~20kHz
Source Internal/External
Modulation
waveform
Sine, Square, Ramp, Arbitrary(except DC)
External Modulation
range
-6V~+6V (maximum width deviation)
Sweep(CH1/CH2)
Carrier Sine, Square, Ramp, Arbitrary(except DC)
Type linear/logarithmic
Direct Up/down
Sweep time 1ms~500s
Trigger source Manual, external, internal
Burst(CH1/CH2)
Waveform Sine, Square, Ramp, Pulse, Arbitrary(except DC)
Type Count(1~50,000 periods),infinite, Gated
Start/Stop phrase 0°~+360°
Internal period 1μs~500s
Gated source External trigger
Trigger source Manual, External or Internal
Rear Panel Connector
External modulation
±6V=100% modulation>5kΩ input impedance
External trigger TTL compatible
Note: The external input voltage cant be over ±6V, otherwise instrument gets damaged.
Trigger Input
Input Level TTL compatible
Slope Up or down (optional)
Pulse width >100ns
Input impedance >5kΩ,DC coupling
Trigger Output
Voltage level TTL compatible
Pulse width >400ns
Output impedance 50Ω (typical)
Max. frequency 1MHz