User Manual

SIGLENT
User Manual 93
UART/RS232 Triggering and Serial Decode
Please in order of Setup for UART/RS232 Signals”, UART/RS232Triggering
and UART/RS232 Decode” to trigger and decode the signals.
Setup for UART/RS232 Signals
1. Press the Decode key to enter the DECODE function menu.
2. Press the Decode softkey and select the desired slot (Decode1 or Decode2).
3. Press Protocol softkey and then select UART by turning Universal Knob.
4. Press Signal softkey to enter the SIGNAL menu as Figure 50 shows.
Figure 41 UART SIGNAL Menu
5. Set RX:
1) Press RX to select the channel that is connected to the RX signal.
2) Press first Threshold key to set the RX signals threshold voltage level by
Universal Knob. The threshold voltage level is for decoding, and it will be regard
as the trigger voltage level when set the trigger type to serial.
6. Set TX:
a. Press TX to select the channel that is connected to the TX signal.
b. Press first Threshold key to set the TX signals threshold voltage level by
Universal Knob. The threshold voltage level is for decoding, and it will be regard
as the trigger voltage level when set the trigger type to serial.
7. Press softkey to return previous menu.
8. Press the Configure softkey to enter BUS CONFIG menu.