Interpreting CAN Decode.
The frame of decoding result:
Arbitration field is displayed in frame
Control field is displayed in frame
Data field is displayed in frame
CRC field is displayed in frame
The list of decoding result:
NO the number of frames in screen.
TIME (timestamp) the horizontal displacement between current frame and trigger
position.
TYPE the type of frames, D represents data frame, R represents remote frame.
ID the id of frames, the oscilloscope can automatically detect the length
of frames id (11 bits or 27 bits).
LENGTH the length of data field.
DATA the value of data field.
CRC the value of CRC (Cyclic Redundancy Check) field.
ACK Acknowledgment bit.