SHS800X SHS1000X Handheld Digital Oscilloscope Data Sheet Rev. 01B Feb. 2022 0 WWW.SIGLENT.
SHS820X/SHS1202X SHS810X/SHS1102X Product Overview SIGLENT’s Handheld Digital Oscilloscopes include the SHS800X and SHS1000X models. Both feature 2 analog oscilloscope input channels and are available in 200 MHz and 100 MHz analog bandwidths, a single ADC with 1 GSa/s maximum sample rate, and a single memory module with 12 Mpts memory depth. When two channels are enabled, each channel has sample rate of 500 MSa/s and a standard record length of 6 Mpts.
SHS800X&SHS1000X Series Handheld Digital Oscilloscope Models and Key Specifications Model Bandwidth Sample rate (Max.) Channels Memory depth (Max.) Waveform capture rate (Max.) Trigger type Serial Trigger and decoder Data Logger(Recorder) I/O Max input Voltage (Scope) Max input Voltage (Meter) Probe Display Weight 2 SHS810X SHS820X SHS1102X SHS1202X 100 MHz 200 MHz 100 MHz 200 MHz Two-channel share a single 1 GSa/s ADC. When two channels are enabled, each channel has a maximum sample rate of 500 MSa/s.
SHS800X&SHS1000X Series Handheld Digital Oscilloscope Functions & Characteristics Front panel and back panel Front panel of the SHS800X series Rear of the SHS800X series Large bright 5.6-inch TFT -LCD display with 640 * 480 resolution. The most commonly used functions are accessible using 8 different one-button operation keys: Run/Stop, Auto Setup, Default, Cursor, Measure, Display/Persist, Clear Sweep, and Print. More function shortcuts are available combined with the shift button.
SHS800X&SHS1000X Series Handheld Digital Oscilloscope 256-Level Intensity Grading and Color Temperature Display SPO display technology provides fast refresh rates. The resulting intensity-graded trace is brighter for events that occur with more frequency and dims when the events occur with less frequency.
SHS800X&SHS1000X Series Handheld Digital Oscilloscope 1M points used to calculate the FFT The new math co-processor enables FFT analysis of incoming signals using up to 1 M samples per waveform. This provides high-frequency resolution with a fast refresh rate. The FFT function also supports a variety of window functions so that it can adapt to different spectrum measurement needs. Support Peaks, Markers, a variety of numbers.
SHS800X&SHS1000X Series Handheld Digital Oscilloscope Adapter/Battery Wall power using the supplied adapter SHS800X/SHS1000X supports adapter power supply and battery power supply. After connecting the adapter, the battery enters into charging mode. The adapter provides a maximum 4 A output current. Battery powered SHS800X/SHS1000X uses a UL2054 certified lithium battery package. The battery capacity of 6900 mAh can guarantee long-term operation without an external power supply for up-to 5.
SHS800X&SHS1000X Series Handheld Digital Oscilloscope Specifications Oscilloscope Acquisition System Model Sampling Rate (Max.) SHS800X 1 GSa/s (single channel), 500 MSa/s (two channels) Memory Depth (Max.) Peak Detect Average ERES Max 12 Mpts/Ch (single channel), 6 Mpts/Ch (two channels) 2 ns Averages:4,16, 32,64,128,256,512,1024 Enhance bits:0.5, 1.5, 2, 2.
SHS800X&SHS1000X Series Handheld Digital Oscilloscope Trigger System Mode Level Hold off range Coupling Coupling Frequency Response Accuracy (typical) Sensitivity Jitter Displacement Edge Trigger Slope Source Slope Trigger Slope Limit Range Auto, Normal, Single Internal: ±4.5 div from the center of the screen 80 ns- 1.
SHS800X&SHS1000X Series Handheld Digital Oscilloscope Limit Range Time Range Resolution Serial Trigger I2C Trigger Condition Source(SDA/SCL) Data format Limit Range Data Length R/W bit SPI Trigger Condition Source(CS/CL/Data) Data format Data Length Bit Value Bit Order UART Trigger Condition Source(RX/TX) Data format Limit Range Data Length Data Width Parity Check Stop Bit Idle Level Baud Rate(Selectable) Baud Rate (Custom) CAN Trigger Condition Source ID Data Format Data Length Baud Rate LIN Trigger Cond
SHS800X&SHS1000X Series Handheld Digital Oscilloscope Signal Edge Select Idle Level Bit Order Threshold List SCL, MISO, MOSI, CS (2 channel scopes can only use 2 signal) identifiers Rising, Falling Low, High MSB, LSB -4.5 - 4.5 div 1- 7 lines UART Signal Data Width Parity Check Stop Bit Idle Level Threshold List RX, TX 5,6,7,8 bits None, Odd, Even, Space, Mark 1, 1.5, 2 bits Low, High -4.5 - 4.5 div 1- 7 lines CAN Signal Source Threshold List CAN_H, CAN_L CAN_H, CAN_L, CAN_H-CAN_L -4.5 - 4.
SHS800X&SHS1000X Series Handheld Digital Oscilloscope Statistics When Statistics is On, it shows the Mean, Min, Max, Standard Deviation of time from the trigger to each rising edge at the 50% crossing in multiple frames (number = Count). The Current shows the time of the current frame from the trigger to the last rising edge at the 50% crossing.
SHS800X&SHS1000X Series Handheld Digital Oscilloscope DC Current[2] [5] AC Current[2] [5] (45Hz~400Hz) Resistance Capacitance Diode 60.00 mA 600.0 mA 6.000 A 10.00 A 10 uA 100 uA 1 mA 10 mA 60.00 mA 600.0mA 6.000 A 10.00 A 600.0 Ω 6.000 kΩ 60.00 kΩ 600.0 kΩ 6.000 MΩ 60.00 MΩ 40.00 nF 400.0 nF 4.000 uF 40.00 uF 400.0 uF 10 uA 100 uA 1 mA 10 mA 0.1 Ω 1Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 0.01 nF 0.
SHS800X&SHS1000X Series Handheld Digital Oscilloscope 1 V/m(2.0 GHz to 2.7 GHz) Electrical fast transients (EFT) IEC 61000-4-4/EN 61000-4-4 2 kV (Input AC Power Ports) Surges IEC 61000-4-5/EN 61000-4-5 1 kV (Line to line) Radio-frequency continuous conducted Immunity IEC 61000-4-6/EN 61000-4-6 3 V, 0.
SHS800X&SHS1000X Series Handheld Digital Oscilloscope Probes and Accessories Probe Picture Model Specifications &Description Bandwidth: 100 MHz, PP510 1X/10X, 1 M/10 Mohm,1X CATII 150 V, 10X CATII 300 V Passive Bandwidth: 200 MHz, PP215 1X/10X, 1 M/10 Mohm,1X CATII 150 V, 10X CATII 300 V High Voltage Bandwidth: 250 MHz, PB925 Passive 10X Fixed, 10 Mohm, CATIII 600 V, CATII 1000 V Bandwidth: 200 KHz, Max.
SHS800X&SHS1000X Series Handheld Digital Oscilloscope Bandwidth: 5 MHz, CP5500 Max. continuous current: 500 Arms, Peak current: 750 A Switch Ratio: 100 mV/A, 10 mV/A, Accuracy: 100 mV/A (± 1% ± 10 mA), 10 mV/A(±1% ± 100 mA), DC 12 V/1.
SHS800X&SHS1000X Series Handheld Digital Oscilloscope SCD600MA Sampling Resistance: 0.5 Ω, Max. Working Current: 600 mA. Current Adapter SCD10A Sampling Resistance: 5 mΩ, Max. Working Current: 10 A,10 sec. Input Voltage: 9-26 V DC, Output current: 0-4 A, Max output power:40 W, Charging efficiency:>85%, Smart Battery GSCH4000A Charger Dimensions(L x W x H): 180 mm*92 mm*58 mm, Weight without battery: 235 g. Color: Black, Carrying Bag Dimensions(L x W x H): 325 mm*310 mm*95 mm, Weight: 200 g.
SHS800X&SHS1000X Series Handheld Digital Oscilloscope Ordering Information Ordering information Product Name Standard Accessories Optional Accessories SHS820X 200 MHz SHS810X 100 MHz SHS1202X 200 MHz Isolated Input SHS1102X 100 MHz Isolated Input USB Cable -1 Quick Start -1 Passive Probe -2 Certification -1 Power Adapter -1 Battery -1 SCD600MA current measurement adapter -1 SCD10A current measurement adapter -1 Carrying Bag -1 Isolated Front End STB Demo Source High Voltage Probe Current Probes Differen