Signal Period Mode
Defines the way the resulting signal period of the multicarrier waveform is
calculated. The resulting period is always calculated for all carriers in the carrier
table. Use the "Carrier Table > Info" function to obtain information on the sample
rate and file length data of each carrier.
Longest File Wins: The longest I/Q file in the carrier table defines the resulting
signal period. Shorter I/Q files are periodically repeated.
Shortest File Wins: The shortest I/Q file in the carrier table defines the resulting
signal period. Only the first part of longer I/Q files is used.
"LCM": The signal period is defined by the least common multiple of the
periods of all waveform files in the carrier table.
"User": The signal period is set manually (Signal Period). Shorter I/Q files are
repeated periodically, and only the first part of longer I/Q files is used.
Signal Period
This item is only displayed when the "Signal Period Mode" is set to "User". Click this
item to manually set the signal period of current multi carrier.