User Manual

SIGLENT
SSG5000X User Manual 121
Sampling Rate
The item displays the sampling rate of the current multi carrier signal according to
the waveform setting in the carrier table.
Create and Load
Click this item, the current multicarrier will be created and loaded into the volatile
memory according to the set waveform name, and the multicarrier will be played
automatically.
Multi carrier creation process
To create a multicarrier waveform file, follow these steps:
1) Enter the "Carrier Table", add each carrier as required, and configure the
frequency, power, phase and other parameters of carriers. You can also use
the “Assistant” settings function to add multiple carriers to the carrier list at a
time.
2) Set the "signal period" and "power reference" of the multicarrier signal to be
generated.
3) Name the new multicarrier in "waveform name".
4) Finally, click "Create and Load" to add the new multi carrier to the volatile