Sweep Times
Select LF->LF Sweep ->Sweep Time to define the duration of the individual sweep
steps. The “Dwell Time” set by the user is used as the step time of the sweep.
Trigger Mode
Select LF->LF Sweep->Trigger Mode to select the LF frequency sweep mode. If you
change the sweep mode during the execution, the signal generator stops the
sweep and starts with the next trigger event at the initial value.
1. Auto
Generate a continuously repeating sweep signal immediately after activating the
sweep mode.
2. Key
Generate a single sweep cycle after a trigger event. The sweep steps within the
cycle are performed automatically, controlled by the dwell time. If one cycle is
completed, the instrument waits for the next trigger event.
3. Ext
Generate a single sweep cycle when an external trigger event occurs.
Sweep Shape
Select LF->LF Sweep->Sweep Shape to select the waveform shape of the sweep