Instruction manual
26
and then validate with the .
Proceed in the same way for the minutes and
then the seconds.
Enter the status of the circuit for this program
step, choosing from ON, OFF, 01s (length in
seconds which can be set using the and keys) and DEL (DEL mode
is used to delete the selected step), and then validate with the key.
If the circuit is a melody circuit, you have to
select the melody number and the number of
times it must be played (from 1 to 4).
The validation with the key allows to
move on to the second line.
Select the days on which this program line will have to apply using the
and keys and then select the mode, choosing from:
WEEKLY: WEEKLY mode functions all year with application of bank holidays if
programmed.
HOLIDAYS: HOLIDAYS mode stops weekly (and bank holiday) mode for a
programmed period and activates the programming of the relays with HOLIDAYS
mode.
SPECIAL: SPECIAL mode deactivates weekly and holidays mode and starts the steps
in SPECIAL mode.
PUBLIC HOLIDAYS: the Public holidays mode activates the program step only for the
Public holidays; it has priority over the Sunday programming.
Validate the step with the key.
If you have programmed a length, the value
in seconds is stored and proposed for the
next step.
NOTE: you can press the key on the
rst step of the program or on the time parameter to access the previous step
or a blank step. On the last step, it allows you to add a new step or correct a
previous step.
In this new step, press the key to restore data from the rst line of the
previous step.
The program steps can be entered in any order. After validation, the system
will reorganise the steps by time and then by type.
Cir.12:08:02:00 ---ú
MTWTFS- Weekly 01/01ok
Cir.ô61:08:02:00 M02x1
MTWTFS- Weekly 01/01ok
Cir.12:08:02:00 03sú
MTWTFS- Weekly 02/02ok