11.2 Time output management menu
Programming by PC software allows the time zone differential of each output
to be set with respect to the local time.
This menu can be used to view all the time outputs, modify their status (Start/
Stop), congure the DHF distribution in Init mode and congure the “impulse”
and “D1D2” distribution.
This menu allows you also to congure the impulse output (Impuls 01) to
provide TBT 24VDC (1A) power supply.
To go to the SIGMA time output management
menu, validate the option in the technician
menu with the key,
The following screen is displayed :
You can view the different options and
change the values using the and
keys.
You can go through the different outputs by
validating using the key.
The 3 outputs (Impulse 01, Afnor 02 and
DHF03) are not programmable with a time
zone differential.
The placing of a DHF output in “INIT” status
is active for 4 hours before return to START mode (The init mode display is
alternating with the normal display during this period).
This menu can be used to set the power of the DHF output with a choice of
25mW / 125mW (by default) / 500mW and assign the system address from 1
to 4 (1 by default).
Buzzer mode allows you to activate a buzzer on the secondary transmitters in
order to identify them.
For an “impulse” or “D1D2” output, the
key can be used to go to the conguration
menu.
Remark: the “D1D2” menu appears only if the relays have been assigned to
Time outputs ok
Relay setting õ
D1D2 minute:06s ú
START 00:00 ok
Afnor 02: START ú
ok
DHF 03 : INIT ú
125mW channel:1 ok
D1D2 minute:06s ú
START 00:00 ok