3.1.5 Motor data
Electrical Data
Identcode Rated voltage System Rated
characteristic frequency power
S3 ph, IP 55 220-240 V/380-420 V 50 Hz 0.25 kW
250-280 V/440-480 V 60 Hz 0.25 kW
M1 ph AC, IP 55 230 V ±5 % 50/60 Hz 0.18 kW
N1 ph AC, IP 55 115 V ±5 % 60 Hz 0.18 kW
L1 3 ph, II2GEEXeIIT3 220-240 V/380-420 V 50 Hz 0.18 kW
L2 3 ph, II2GEEXdIICT4 220-240 V/380-420 V 50 Hz 0.18 kW with PTC thermistor, speed adjustment range 1:5
P1 3 ph, II2GEEXeIIT3 250-280 V/440-480 V 60 Hz 0.18 kW
P2 3 ph, II2GEEXdIICT4 250-280 V/440-480 V 60 Hz 0.21 kW with PTC thermistor, speed adjustment range 1:5
R3 ph, IP 55 230 V/400 V 50/60 Hz 0.37 kW with PTC thermistor, speed adjustment range 1:20
with external fan 1 ph 230 V; 50/60 Hz
V0 1 ph, IP 55 230 V ±5 % 50/60 Hz 0.37 kW variable speed motor with integrated
frequency converter
For more details you can request the motor specification sheets. Custom motors and/or custom
motor flanges are available on request.
WARNING
Only EX pump: Please thoroughly read the chapter “Important Additions for Metering
Pumps in the EX Area” of the “General Operating Instructions ProMinent Motor Metering
Pumps and Hydraulic Accessories”!
Technical data
3.1.4 Dimensions Sigma/ 2 S2Ba
Fig. 14
61_01_101_00_27_73
T
8
120
44
A
K
E
Ø N
120
V
Ø D
191225
Ø M
Ø S
170
217
Ø P
A
A-A
Dimensions Sigma/ 2 (in mm)
Motor flange Ø P Ø M Ø N Ø S Ø D E T K L V
B 14/105 105 85 70 7 19 29 3,5 5 16,3 288
56 C/138 5.43 5.88 4.5 0.43 0.62 1.14 0.16 0.2 0.72 12.2
B 14/160 160 130 110 9 14 29 6 5 16,3 290
B 14/200 200 165 130 11 19 52,5 6 6 21,8 323
B 5/140* 140 115 95 9,5 11 26 3,5 4 12,8 230
* assembly without adapt flange direct on pump housing
BA_SI_036_06_10_EN.p65 08.06.2010, 11:38 Uhr26