5.8 Function and fault Indicator
The operating and fault statuses are indicated by the three LED indicators
and the
“Error”
identifier on the LCD screen, see also the "Trouble‐
shooting" chapter.
5.9 LCD screen
If a fault occurs, the identifier
“Error”
appears and an additional error mes‐
sage.
5.10 LED indicators
Operating indicator (green): The operating indicator illuminates if during
pump operation there are no incoming fault or warning messages. It goes
out briefly with every stroke.
Warning indicator (yellow): The warning indicator illuminates, if the pump
electronics detect a condition which may lead to a fault, e.g. "liquid level
low 1st stage".
Fault indicator (red): The fault indicator illuminates, if a fault occurs e.g.
liquid level low 2nd stage".
5.11 Hierarchy of operating modes, functions and fault statuses
The different operating modes, functions and fault statuses have a dif‐
ferent effect on if and how the pump reacts.
The following list shows the order:
1. - Priming
2. - Fault, Stop, Pause
3. - Auxiliary frequency (external frequency changeover)
4. - Manual, external contact
Comments:
re 1 - "Priming" can take place in any mode of the pump (providing it is
functioning).
re 2 - "Fault", "Stop" and "Pause" stop everything apart from "Priming".
re 3 - The stroke rate of "Auxiliary rate" always has priority over the
stroke rate specified by an operating mode or priority 4.