Operating instructions

CAUTION!
Danger from incorrectly operated or inadequately maintained
pumps
Danger can arise from a poorly accessible pump due to
incorrect operation and poor maintenance.
Ensure that the pump is accessible at all times.
Adhere to the maintenance intervals.
Position the pump so that control elements such as the stroke length
adjustment knob, the indicating dial A or the oil inspection window are
accessible.
In so doing, ensure there is enough space to carry out an oil change (vent
screws, oil drain plugs, oil trough ...).
1 Discharge valve
2
Dosing head
3 Suction valve
Ensure there is sufficient free space (f) around the dosing head as well as
the suction and discharge valve so that maintenance and repair work can
be carried out on these components.
Capacity too low
If the valves of the liquid end do not stand upright, they
cannot close correctly.
The discharge valve must be upright.
Capacity too low
Vibrations can disturb the valves of the liquid end.
Secure the metering pump so that no vibrations can
occur.
Take the dimensions (m) for the fastening holes from the appropriate
dimensional drawings or data sheets.
Fasten the pump base to the supporting floor using suitable screws.
Space requirement
A
A
P_MOZ_0018_SW
Fig. 12
1
3
2
f
f
f
P_MOZ_0017_SW
Fig. 13
Liquid end alignment
Fastening
DNm
m
P_MOZ_0015_SW
Fig. 14
Assembly