Operating instructions

CAUTION!
Warning of unnoticed diaphragm rupture
Only above approximately 2 bar system back pressure is a
signal generated upon a diaphragm rupture.
Only rely on the diaphragm rupture sensor at back pres‐
sures greater than 2 bar.
7.2 Installation, electrical
WARNING!
Danger of electric shock
Unprofessional installation may lead to electric shocks.
All cable cores cut to length must be provided with cable
end sleeves.
The Installation, electrical of the device may only be
undertaken by technically trained personnel.
CAUTION!
Warning about personal and material damage
Also observe the "General Operating Instructions for ProMi‐
nent
®
Motor-Driven Metering Pumps and Hydraulic Accesso‐
ries"!
What requires electrical installation?
n Level switch
n Diaphragm rupture sensor (Option)
n Dosing monitor (option)
n Relay (option)
n External control
n mA output (option)
n Bus connector (option)
n Timer (option)
n Pump, power supply
7.2.1 Control connectors
CAUTION!
Incoming signals can remain without effect
If the universal control wire, the external/pacing cable or the
level monitoring cable is shortened below 1.20 m, the pump
does not detect that it is connected. Consequently a warning
message (for example) can be suppressed.
Do not shorten this cable below 1.20 m.
Connect the plugs of the level switch, diaphragm rupture sensor and
dosing monitor to the corresponding sockets on the front side of the con‐
trol. In case of uncertainty - see chapter "Overview of equipment and con‐
trol elements"
General safety notes
What requires electrical installation?
Level switch, diaphragm rupture sensor
(option) and dosing monitor (option)
Installation
27