Operating instructions

You can also activate the "Memory" function extension (identifier
“Mem”
appears on the LCD screen;
“Mem”
= memory). When "Memory" is acti‐
vated, the pump software adds up the remaining strokes , which could not
be processed, up to the maximum capacity of the stroke memory of
65,535 strokes. If this maximum capacity is exceeded, the pump goes into
fault mode.
You can thus optimally match the pump to the process in question, for
example in conjunction with contact water meters.
8.5.4 "Batch" operating mode settings (BATCH menu)
Alongside those described in more detail in the chapter "Programmable
function settings (SET menu)" the
“BATCH”
menu is also available in
“Batch”
operating mode via the
“SET”
menu.
Continuous
display
B0092
Fig. 36
The operating mode
“Batch”
is a variant of the operating mode
“Contact”
- in the first place see "
“Contact”
operating mode settings". Here also, you
can select a number of strokes (no fractions, only integers from 1 to
65535), but also a metering quantity (Batch). To change between the input
"Number of strokes" and "Metering quantity" press the
[ i ]
key 1x under
the corresponding menu option (see "Operating / adjustment overview" in
the appendix).
“Batch”
operating mode is intended for large metering quantities.
The metering can be triggered either by pressing the
[P]
key or by a pulse
received via the "External control" terminal.
The number of received pulses, which could not yet be processed, is
stored by the pump control in the stroke memory. The stroke memory is
limited to the Batch size if "Memory" is not activated, with "Memory" to
65535 strokes.
You can delete it by changing to another operating mode.
You can also activate the "Memory" function extension (identifier
“Mem”
appears on the LCD screen;
“Mem”
= memory). When "Memory" is acti‐
vated, the pump software adds up the remaining strokes , which could not
be processed, up to the maximum capacity of the stroke memory of
65,535 strokes. If this maximum capacity is exceeded, the pump goes into
fault mode.
You can thus optimally match the pump to the process in question, for
example in conjunction with contact water meters.
8.6 Programmable function settings (SET menu )
Setting menus are available in the SET menu in all operating modes for
the following programmable functions:
n Calibrate (
“CALIB”
menu)
n Auxiliary rate (
“AUX”
menu)
n Flow (
“FLOW”
menu; (only available if a dosing monitor is connected)
"Memory" function extension
"Memory" function extension
Adjustment
45