Operating instructions

Consequence:
n The corresponding continuous displays indicate the calibrated values.
n Total number of strokes and total litres are set to "0" by calibrate.
n The pump is in the STOP state.
8.6.2
“Auxiliary frequency” function settings (AUX menu)
Continuous
display
B0094
Fig. 38
The programmable function "Auxiliary frequency" facilitates the activating
of an auxiliary stroke rate, which can be set in the
“AUX”
menu. It can be
activated via the "External control" terminal. If the auxiliary frequency is
being used, then the identifier
“Aux”
appears in the LCD screen.
This auxiliary frequency has priority over the stroke rate, which is specified
by the currently selected operating mode.
8.6.3 “Flow” function settings (FLOW menu)
Continuous
display
B0095
Fig. 39
The
“FLOW”
menu only appears if a dosing monitor is connected to the
"Dosing monitor" terminal. The dosing monitor records the individual
metering strokes of the pump at the discharge connector and reports them
back to the pump control. If this feedback is sequentially missing for as
often as set in the
“FLOW”
menu (after a fault or too low metering), the
pump is stopped.
8.7 Setting the code (CODE menu)
In the
“CODE”
menu, you can enter whether you want to block parts of
the adjustment options.
Continuous
display
B0096
Fig. 40
Adjustment
47