Operating instructions

To change a value, see below, directly in the corresponding continuous
display, press one of the
[arrow keys]
until the
[Set]
identifier appears.
(The delay period has been programmed in to prevent unintentional
changing of values.)
If
“CODE 2”
was set, then after pressing an
[arrow key]
, the code must
first be entered.
The directly changeable variables are in detail:
In operating modes
“Manual”
,
“Contact”
and
“Batch”
:
You can change the stroke rate in the
“Stroke rate”
continuous display.
In operating mode
“Manual”
:
You can change the capacity in the "Capacity" continuous display.
The factor is the number of strokes which are triggered upon an external
pulse or pressing of key
[P]
(only in
“Batch”
operating mode).
In operating mode
“Batch”
:
You can change the factor from the "Remaining strokes" continuous dis‐
play. A couple of seconds after your have set the factor, the pump control
jumps back to the initial continuous display.
Press the
[P]
key for 10 s to display the program versions.
“V1052”
+
“X1010”
Under “LOAD3” release the [P] key immediately!
In operating mode
“Batch”
:
You can change the batch size from the "Batch size/Remaining litres" con‐
tinuous display. A couple of seconds after your have set the factor, the
pump control jumps back to the initial continuous display.
Simultaneous pressing of the two
[arrow keys]
triggers the "Priming" func‐
tion.
Fault displays are acknowledged by brief pressing of the
[P]
key.
Changing directly changeable variables
Stroke rate
Capacity
Factor
Displaying the program versions
Batch size
Priming
Fault acknowledgement